{"title":"Data Center","description":"","products":[{"product_id":"data-center-02","title":"LMMR Fiber Management Rack","description":"\u003cp\u003eLitech’s LMMR Fiber Management Rack are designed for terminating optical fiber in data center or exchanges where ultra-high density fiber termination and patching is required. LMMR rack features a modular system for splicing and patching with flexible cable management systems. All cable are front accessible with individual slide out splice organizer tray for easy fiber maintenance. One LMMR rack is able to accommodate up 2880 SC Ports (with 24 fiber per tray) and 4320 LC Ports (36 fiber per tray). A cost effective solution for ultra-high density optic fiber management.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTotal fiber management system.\u003c\/li\u003e\n\u003cli\u003eCompact design for space saving.\u003c\/li\u003e\n\u003cli\u003eSuperior cable management for incoming cable and patchcords.\u003c\/li\u003e\n\u003cli\u003eBend limiting tubes to guide fiber from cable to splice tray to avoid any kinked fibers.\u003c\/li\u003e\n\u003cli\u003eSpace for access patch cables.\u003c\/li\u003e\n\u003cli\u003eSupport Ultra-High Density connections.\u003c\/li\u003e\n\u003cli\u003eSlide out tray mechanism for easy spliced fiber access.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Litech","offers":[{"title":"1440 Port \/ SC","offer_id":52077852131644,"sku":null,"price":99999999.0,"currency_code":"MYR","in_stock":true},{"title":"2880 Port \/ SC","offer_id":52077852164412,"sku":null,"price":99999999.0,"currency_code":"MYR","in_stock":true},{"title":"2880 Port \/ LC","offer_id":52077852197180,"sku":null,"price":99999999.0,"currency_code":"MYR","in_stock":true},{"title":"5760 Port \/ LC","offer_id":52077852229948,"sku":null,"price":99999999.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0865\/5644\/2940\/files\/LMMR_Fiber_Management_Rack_3459838e-4de5-4d23-8697-15cb3c875d8e.jpg?v=1757560585"},{"product_id":"data-center-03","title":"19\" to 21\" Extension Bracket (one pair)","description":"","brand":"Litech","offers":[{"title":"Default Title","offer_id":51628956188988,"sku":null,"price":8.5,"currency_code":"MYR","in_stock":true}]},{"product_id":"data-center-04","title":"Zinc Alloy Handle Lock","description":"","brand":"Litech","offers":[{"title":"Default Title","offer_id":51628956221756,"sku":null,"price":95.0,"currency_code":"MYR","in_stock":true}]},{"product_id":"data-center-18","title":"LDWA Rear Heat Door Exchanger - Liquid Cooling Solution","description":"\u003cp\u003eLitech Rear Heat Door Exchanger is an innovative liquid cooling solution designed to enhance thermal efficiency in various applications. The Rear Heat Door Exchanger is a crucial component for enhancing thermal efficiency across various applications. With its ability to optimize heat transfer, improve energy efficiency, and adapt to different environments, this exchanger is indispensable in modern engineering solutions. By incorporating a Rear Heat Door Exchanger into your systems, you can achieve significant improvements in performance, sustainability, and operational cost-effectiveness.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSimple installation with heat exchanger and fan seamlessly combined into a single unit.\u003c\/li\u003e\n\u003cli\u003eAdjustable fan speed and water valve opening based on needs, allowing for precise control of the cooling capacity.\u003c\/li\u003e\n\u003cli\u003eAn intelligent control program oversees and manages the unit's operation in real-time for a safe and stable performance.\u003c\/li\u003e\n\u003cli\u003eExpert-level fault diagnosis, simplifying both operation and maintenance.\u003c\/li\u003e\n\u003cli\u003eSupports Modbus RTU, with the option of TCP\/IP connectivity.\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Specification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"border-collapse: collapse; width: 1076px; height: 186px;\" width=\"959\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"width: 269.667px;\" width=\"230\"\u003e \u003ccol style=\"width: 347.667px;\" width=\"309\"\u003e \u003ccol style=\"width: 457.667px;\" width=\"420\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; width: 173pt;\" width=\"230\" class=\"xl64\" height=\"19\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 232pt; text-align: center; height: 19.6px;\" width=\"309\" class=\"xl68\"\u003e\u003cstrong\u003eLDWA-25D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 315pt; text-align: center; height: 19.6px;\" width=\"420\" class=\"xl69\"\u003e\u003cstrong\u003eLDWA-50D\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; width: 173pt;\" width=\"230\" class=\"xl63\" height=\"19\"\u003eRefrigeration capacity (kW)\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 232pt; text-align: center; height: 19.6px;\" width=\"309\" class=\"xl65\"\u003e25\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; text-align: center; height: 19.6px;\" class=\"xl66\"\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd style=\"height: 20px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 173pt;\" width=\"230\" class=\"xl63\" height=\"20\"\u003eInlet\/Outlet liquid temperature (°C)\u003c\/td\u003e\n\u003ctd style=\"border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 547pt; text-align: center; height: 20px;\" width=\"729\" class=\"xl70\" colspan=\"2\"\u003e20\/28\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd style=\"height: 20px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 173pt;\" width=\"230\" class=\"xl63\" height=\"20\"\u003eInlet and return air temperature (°C)\u003c\/td\u003e\n\u003ctd style=\"border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 547pt; text-align: center; height: 20px;\" width=\"729\" class=\"xl70\" colspan=\"2\"\u003e24\/38\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 173pt;\" width=\"230\" class=\"xl63\" height=\"19\"\u003eAir volume (m³)\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 232pt; text-align: center; height: 19.6px;\" width=\"309\" class=\"xl67\"\u003e6000\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; text-align: center; height: 19.6px;\" class=\"xl66\"\u003e12000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 173pt;\" width=\"230\" class=\"xl63\" height=\"19\"\u003eRated Power (kW)\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 232pt; text-align: center; height: 19.6px;\" width=\"309\" class=\"xl67\"\u003e1.1\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; text-align: center; height: 19.6px;\" class=\"xl66\"\u003e2.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd style=\"height: 20px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 173pt;\" width=\"230\" class=\"xl63\" height=\"20\"\u003eMaximum allowed power (kW)\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 232pt; text-align: center; height: 20px;\" width=\"309\" class=\"xl67\"\u003e1.5\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; text-align: center; height: 20px;\" class=\"xl66\"\u003e2.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd style=\"height: 20px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 173pt;\" width=\"230\" class=\"xl63\" height=\"20\"\u003eSupply air static pressure (Pa)\u003c\/td\u003e\n\u003ctd style=\"border-left-width: medium; border-left-style: none; border-left-color: currentcolor; text-align: center; height: 20px;\" class=\"xl72\" colspan=\"2\"\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 173pt;\" width=\"230\" class=\"xl63\" height=\"19\"\u003ePipe interface (DN)\u003c\/td\u003e\n\u003ctd style=\"border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 547pt; text-align: center; height: 19.6px;\" width=\"729\" class=\"xl74\" colspan=\"2\"\u003eDN32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 173pt;\" width=\"230\" class=\"xl63\" height=\"19\"\u003eFan hot swap\u003c\/td\u003e\n\u003ctd style=\"border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 547pt; text-align: center; height: 19.6px;\" width=\"729\" class=\"xl70\" colspan=\"2\"\u003eSupport\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 173pt;\" width=\"230\" class=\"xl63\" height=\"19\"\u003ePower supply system\u003c\/td\u003e\n\u003ctd style=\"border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 547pt; height: 19.6px; text-align: center;\" width=\"729\" class=\"xl70\" colspan=\"2\"\u003e208V-240V\/1Ph\/50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 173pt;\" width=\"230\" class=\"xl63\" height=\"19\"\u003eUnit size (W*D*H) (mm)\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 232pt; height: 19.6px; text-align: center;\" width=\"309\" class=\"xl67\"\u003e600 X 320 X2000\/2200\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; height: 19.6px; text-align: center;\" class=\"xl66\"\u003e600 X 320 X 2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Litech","offers":[{"title":"Default Title","offer_id":51628959203644,"sku":null,"price":99999999.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0865\/5644\/2940\/files\/LDWA_Rear_Heat_Door_Exchanger..jpg?v=1775188425"},{"product_id":"data-center-19","title":"LDWW Rack Mount - Coolant Distribution Unit (CDU)","description":"\u003cp\u003eLitech Rack Mount Coolant Distribution Unit (CDU) is a critical component for effective thermal management in modern IT environments. With its ability to enhance cooling efficiency, optimize space, and improve system reliability, this unit is essential in data centers, telecommunications, and high-performance computing facilities. By incorporating a Rack Mount CDU into your cooling infrastructure, you can ensure that your systems operate at peak performance while minimizing the risks associated with overheating.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDual pump redundancy design that seamlessly activates the standby pump in the event of a primary pump failure.\u003c\/li\u003e\n\u003cli\u003eIncorporates a high-efficiency stainless steel plate heat exchanger characterized by a compact design and exceptional corrosion resistance.\u003c\/li\u003e\n\u003cli\u003eEquipped with an intelligent PLC control program which offers real-time monitoring and stable operation.\u003c\/li\u003e\n\u003cli\u003eAdvanced fault diagnosis made easy with straightforward operation and maintenance.    \u003cbr\u003eSupport Modbus RTU, optional TCP\/IP.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Specification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable height=\"174\" style=\"border-collapse: collapse; width: 1293px; height: 236.4px;\" width=\"1101\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"width: 568px;\" width=\"278\"\u003e \u003ccol style=\"width: 257px;\" width=\"309\"\u003e \u003ccol style=\"width: 467px;\" width=\"514\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; width: 209pt;\" width=\"278\" class=\"xl64\" height=\"19\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 232pt; text-align: center; height: 19.6px;\" width=\"309\" class=\"xl68\"\u003e\u003cstrong\u003eLDWW30-20C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 386pt; text-align: center; height: 19.6px;\" width=\"514\" class=\"xl69\"\u003e\u003cstrong\u003eLDWW50-25C\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; width: 209pt;\" width=\"278\" class=\"xl63\" height=\"19\"\u003eRefrigeration capacity (kW)\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 232pt; text-align: center; height: 19.6px;\" width=\"309\" class=\"xl65\"\u003e30\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; text-align: center; height: 19.6px;\" class=\"xl66\"\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd style=\"height: 20px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 209pt;\" width=\"278\" class=\"xl63\" height=\"20\"\u003eSecondary side supply\/return water (°C)\u003c\/td\u003e\n\u003ctd style=\"border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 618pt; height: 20px; text-align: center;\" width=\"823\" class=\"xl71\" colspan=\"2\"\u003e40\/50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd style=\"height: 20px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 209pt;\" width=\"278\" class=\"xl63\" height=\"20\"\u003eSecondary side flow (m³\/h)\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 232pt; height: 20px; text-align: center;\" width=\"309\" class=\"xl67\"\u003e2.6\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 386pt; height: 20px; text-align: center;\" width=\"514\" class=\"xl67\"\u003e4.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 209pt;\" width=\"278\" class=\"xl63\" height=\"19\"\u003eSecondary side interface (DN)\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 232pt; height: 19.6px; text-align: center;\" width=\"309\" class=\"xl67\"\u003eDN20\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; height: 19.6px; text-align: center;\" class=\"xl70\"\u003eDN25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 209pt;\" width=\"278\" class=\"xl63\" height=\"19\"\u003ePrimary side supply\/return water (°C)\u003c\/td\u003e\n\u003ctd style=\"border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 618pt; height: 19.6px; text-align: center;\" width=\"823\" class=\"xl71\" colspan=\"2\"\u003e35\/45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"20\"\u003e\n\u003ctd style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 209pt;\" width=\"278\" class=\"xl63\" height=\"20\"\u003ePrimary side interface (DN)\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 232pt; height: 19.6px; text-align: center;\" width=\"309\" class=\"xl67\"\u003eDN20\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; height: 19.6px; text-align: center;\" class=\"xl70\"\u003eDN25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\" height=\"20\"\u003e\n\u003ctd style=\"height: 20px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 209pt;\" width=\"278\" class=\"xl63\" height=\"20\"\u003eRated power (kW)\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; height: 20px; text-align: center;\" class=\"xl66\"\u003e1.6\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; height: 20px; text-align: center;\" class=\"xl70\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 209pt; text-align: left;\" width=\"278\" class=\"xl63\" height=\"19\"\u003ePrimary side pressure drop (kPA)\u003c\/td\u003e\n\u003ctd style=\"border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 618pt; height: 19.6px; text-align: center;\" width=\"823\" class=\"xl75\" colspan=\"2\"\u003e≤80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 39.2px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 209pt;\" width=\"278\" class=\"xl73\" height=\"38\" rowspan=\"2\"\u003ePower supply system\u003c\/td\u003e\n\u003ctd style=\"border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 618pt; height: 19.6px; text-align: center;\" width=\"823\" class=\"xl71\" colspan=\"2\"\u003e208V-240V\/1Ph\/50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 618pt; text-align: center;\" width=\"823\" class=\"xl71\" height=\"19\" colspan=\"2\"\u003e208V-240V\/1Ph\/50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 209pt; text-align: left;\" width=\"278\" class=\"xl63\" height=\"19\"\u003eUnit size (W*D*H) (mm)\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 232pt; height: 19.6px; text-align: center;\" width=\"309\" class=\"xl67\"\u003e440 x 900 x 177 (4U)\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; height: 19.6px; text-align: center;\" class=\"xl66\"\u003e440 x 900 x 265 (6U)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Litech","offers":[{"title":"Default Title","offer_id":51628959236412,"sku":null,"price":99999999.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0865\/5644\/2940\/files\/LDWW_Rack_Mount..jpg?v=1775188424"},{"product_id":"data-center-20","title":"LDA Rack Airconditioner","description":"\u003cp\u003eLitech LDA Rack Air Conditioner is a cooling system specifically designed to cool individual server racks within a data center. These compact units are installed directly into the server rack to provide targeted cooling, ensuring that sensitive equipment stays at optimal operating temperatures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWidely used for edge computing rack, or single rack air conditioner.\u003c\/li\u003e\n\u003cli\u003ePrecise cooling for electronics devices.\u003c\/li\u003e\n\u003cli\u003eDC variable speed Compressor and Fans to perform dynamic and step-less cooling capacity regulation.\u003c\/li\u003e\n\u003cli\u003eSplit type design with highest efficiency EER up to 3.0.\u003c\/li\u003e\n\u003cli\u003eUsing Electronic Expansion Valve to control refrigerant flow accurately.\u003c\/li\u003e\n\u003cli\u003eDraw and Pull design with convenient access for installation and service.\u003c\/li\u003e\n\u003cli\u003eRate of Sensible Heat goes up to 0.95+.\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Litech","offers":[{"title":"Default Title","offer_id":51628959269180,"sku":null,"price":99999999.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0865\/5644\/2940\/files\/LDA_Rack_Airconditioner..jpg?v=1775188424"},{"product_id":"data-center-21","title":"Rear Door Chilled - Water Cooler","description":"\u003cp\u003eRear door chilled water cooler is installed on the rear door of server racks, directly cooling the discharge air of the cabinet.\u003c\/p\u003e\n\u003cp\u003eCombined with a chiller, it achieves the isolation of cold and hot environments. The main components include casing, EC fans, heat exchange coil, controller, and group control system, aiming to achieve the optimal performance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProximity to Heat Source\u003c\/li\u003e\n\u003cli\u003eBackup Fan Design\u003c\/li\u003e\n\u003cli\u003eElectronically Commutated (EC) Fan\u003c\/li\u003e\n\u003cli\u003eStepless Regulation\u003c\/li\u003e\n\u003cli\u003eHigh Efficiency\u003c\/li\u003e\n\u003cli\u003eEasy Maintenance\u003c\/li\u003e\n\u003cli\u003eSimple Operation    \u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Litech","offers":[{"title":"Default Title","offer_id":51628959301948,"sku":null,"price":99999999.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0865\/5644\/2940\/files\/Rear_Door_Chilled_-_Water_Cooler..jpg?v=1775188423"},{"product_id":"data-center-23","title":"LDWW Cabinet - Coolant Distribution Unit (CDU)","description":"\u003cp\u003eLitech Cabinet Coolant Distribution Unit is engineered for efficient thermal management. It provides a centralized solution for distributing coolant to various components within a cabinet, ensuring consistent cooling across the system. Designed to manage and distribute coolant effectively, the cabinet CDU ensures optimal thermal performance for servers and other heat-generating equipment. With its ability to enhance cooling efficiency, optimize space, and improve system reliability, this unit is crucial in data centers, telecommunications, and high-performance computing facilities. By integrating a Cabinet Coolant Distribution Unit into your cooling infrastructure, you can ensure that your systems operate at peak performance while minimizing the risks associated with overheating.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe dual pump redundant design seamlessly transitions to a backup pump in the event of a single pump failure, ensuring uninterrupted operation.\u003c\/li\u003e\n\u003cli\u003eFeatures a highly efficient stainless steel plate heat exchanger known for its compact design and exceptional resistance to corrosion.\u003c\/li\u003e\n\u003cli\u003eThe internal piping is crafted from stainless steel, guaranteeing a clean and contamination-free system.\u003c\/li\u003e\n\u003cli\u003eEquipped with an intelligent PLC control program which facilitates real-time monitoring and management, ensuring the unit operates safely.\u003c\/li\u003e\n\u003cli\u003eWith expert-level fault diagnosis capabilities, it simplifies both operation and maintenance.\u003c\/li\u003e\n\u003cli\u003eSupport Modbus RTU with an optional TCP\/IP interface.\u003c\/li\u003e\n\u003cli\u003eComes with intuitive color touchscreen interface enhances user interaction, that incorporates multi-tier password settings to safeguard information security.    \u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Litech","offers":[{"title":"Default Title","offer_id":51628959564092,"sku":null,"price":99999999.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0865\/5644\/2940\/files\/LDWW_Cabinet..jpg?v=1775188317"},{"product_id":"data-center-24","title":"LRA Row-Based - Air-Cooled Airconditioner","description":"\u003cp\u003eLitech LRA Row-based Air-Cooled Air Conditioner is designed for the medium and high thermal density data center. It can be installed close to the heat source, shorten the flow path of cold air to accurately process the sensible heat generated by the server. It is the ideal choice for the green energy-saving data center and various electronic equipment rooms.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSmall and medium-sized data centers, modular data centers, cabinet cold (hot) aisle transformation, medium and high thermal density communication equipment and computer rooms, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eKey components are selected from well-known brand.\u003c\/li\u003e\n\u003cli\u003eFull EC inverter design, automatic adjustment of cooling capacity and air volume output.\u003c\/li\u003e\n\u003cli\u003eWet film humidifier, saving 99% of humidification energy.\u003c\/li\u003e\n\u003cli\u003eLinear shape or U shape\" evaporator, large area, small resistance.\u003c\/li\u003e\n\u003cli\u003eCompact outdoor unit, U-shaped design, air return on three sides.\u003c\/li\u003e\n\u003cli\u003eHigh return air temperature design, significantly improved energy efficiency.\u003c\/li\u003e\n\u003cli\u003eFull frontal maintenance, pull-out design.\u003c\/li\u003e\n\u003cli\u003eGroup control, flexible configuration.\u003c\/li\u003e\n\u003cli\u003eOptional power metering function module.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Litech","offers":[{"title":"Default Title","offer_id":51628959596860,"sku":null,"price":99999999.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0865\/5644\/2940\/files\/LRA_Row-Based..jpg?v=1775188317"},{"product_id":"data-center-25","title":"LRC Row-Based Airconditioner (Chilled Water)","description":"\u003cp\u003eLitech LRC Row-Based Air Conditioner (Chilled water) is more suitable for scenarios with limited on-site installation (no need to install outdoor units) while maintaining accurate cooling characteristics close to the heat source, helping the continuous development of green data centers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSmall and medium-sized data centers, modular data centers, cabinet cold (hot) aisle transformation, medium and high thermal density communication equipment and computer rooms, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eKey components are selected from well-known brand\u003c\/li\u003e\n\u003cli\u003eEC centrifugal fan, automatically adjust cooling capacity and air volume output\u003c\/li\u003e\n\u003cli\u003eWet film humidifier, saving 99% of humidification energy\u003c\/li\u003e\n\u003cli\u003eFull cabinet type evaporator, large area, small wind resistance\u003c\/li\u003e\n\u003cli\u003eHigh return air temperature design, energy efficiency significantly improved\u003c\/li\u003e\n\u003cli\u003eFull frontal maintenance, pull-out design\u003c\/li\u003e\n\u003cli\u003eTeamwork networking with flexible configuration\u003c\/li\u003e\n\u003cli\u003eOptional power metering function module    \u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Litech","offers":[{"title":"Default Title","offer_id":51628959859004,"sku":null,"price":99999999.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0865\/5644\/2940\/files\/LRC_Row-Based_Airconditioner..jpg?v=1775188317"},{"product_id":"data-center-26","title":"LRF Row-Based Air Conditioner (Refrigerant Pump)","description":"\u003cp\u003eLRF Row-Based Air Conditioner (Refrigerant Pump) can use atmospheric natural cold source for cooling computer room. It is installed close to the heat source, shorten the flow path of cold air, and accurately process the sensible heat generated by the server. It is an ideal choice for green and energy-saving data centers and all kinds of electronic equipment rooms.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSmall and medium-sized data centers, modular data centers, cabinet cold (hot) aisle transformation, medium and high thermal density communication equipment and computer rooms, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eKey components are selected from well-known brand\u003c\/li\u003e\n\u003cli\u003eFull EC inverter design, automatic adjustment of cooling capacity and air volume output\u003c\/li\u003e\n\u003cli\u003eWet film humidifier, saving 99% of humidification energy\u003c\/li\u003e\n\u003cli\u003eLinear shape or U shape\" evaporator, large area, small resistance\u003c\/li\u003e\n\u003cli\u003eHigh return air temperature design, energy efficiency significantly improved\u003c\/li\u003e\n\u003cli\u003eThree operating modes, automatic switching, real-time adjustment\u003c\/li\u003e\n\u003cli\u003ePump cabinet system series design, high integration, more energy saving unit\u003c\/li\u003e\n\u003cli\u003eThe pump cabinet is integrated on the outdoor side, without requiring additional space for placement\u003c\/li\u003e\n\u003cli\u003eIntegrated efficient energy-saving algorithm, support group control, rotation, cascade    \u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Litech","offers":[{"title":"Default Title","offer_id":51628959891772,"sku":null,"price":99999999.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0865\/5644\/2940\/files\/LRF_Row-Based_Air_Conditioner..jpg?v=1775188316"},{"product_id":"data-center-27","title":"Room-Based (Air-Cooled CRAC)","description":"\u003cp\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLMA Room-based Air-cooled Air conditioner provides precise temperature and humidity control for large and medium-size data rooms. It adopts high efficiency compressor and EC centrifugal fan to meet the requirements of 24 X 7 all-weather continuous operation. It is the ideal choice for green and energy-saving data centers and various electronic equipment rooms. It’s is manufactured with the world’s leading technologies and the most advanced components. Every product is fully tested before ex-factory to ensure performances and reliability.\u003c\/li\u003e\n\u003cli\u003eApplication scenarios: data center, communication equipment and computer room, MRI and CT room, other precision equipment environment, such as precision processing, electronic instrument workshop, museum, archives, high-end wine cellar, medical equipment room, constant temperature and humidity laboratory, etc.\u003c\/li\u003e\n\u003cli\u003eAdopt fully enclosed inverter driven compressors and EC fans to minimize vibration and noise.\u003c\/li\u003e\n\u003cli\u003eHeat exchanger is using high-efficiency inner grooved copper tubes and Hydrophilic fins. Large heat exchanging area for better performances and efficiency.\u003c\/li\u003e\n\u003cli\u003eTwo totally independent refrigerant circuits for 100% redundancy, automatically balances the wear of every component to guarantee longer lifespan and more reliable operation. In case of one of circuit malfunction, the unit can still provide 50% cooling capacity.\u003c\/li\u003e\n\u003cli\u003eMultiple integrated protections, such as high\/low pressure and high discharge temperature protection, unit will shutdown automatically for protection, to avoid damages to the compressors.\u003c\/li\u003e\n\u003cli\u003eAdopt self-developed intelligent monitoring system, 7-inch LCD touch screen, friendly human-machine interface. It provides simple, convenient and real-time control and management of all the product functions, parameters query. Parameters display in graphic curve, with self diagnostic function to assures reliable and smooth operation.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Litech","offers":[{"title":"Default Title","offer_id":51628960153916,"sku":null,"price":99999999.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0865\/5644\/2940\/files\/Room-Based_Air-Cooled_CRAC__1.jpg?v=1775198958"},{"product_id":"data-center-28","title":"Room-Based (Air-Cooled Plus CRAC)","description":"\u003cp\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLMA Room-based Air-cooled Plus Air conditioner provides precise temperature and humidity control for large and medium-size data rooms. It adopts high efficiency compressor and EC centrifugal fan to meet the requirements of 24 X 7 all-weather continuous operation. Every product is fully tested before ex-factory to ensure performances and reliability.\u003c\/li\u003e\n\u003cli\u003eApplication scenarios: data center, communication equipment and computer room, MRI and CT room, other precision equipment environment, such as precision processing, electronic instrument workshop, museum, archives, high-end wine cellar, medical equipment room, constant temperature and humidity laboratory, etc.\u003c\/li\u003e\n\u003cli\u003eAdopt fully enclosed inverter compressors and EC fans to minimize vibration and noise.\u003c\/li\u003e\n\u003cli\u003eMultiple integrated protections, such as high\/low pressure and high discharge temperature protection, unit will shutdown automatically for protection, to avoid damages to the compressors.\u003c\/li\u003e\n\u003cli\u003eAdopt self-developed intelligent monitoring system, 7-inch LCD touch screen, friendly human-machine interface. It provides simple, convenient and real-time control and management of all the product functions, parameters query. Parameters display in graphic curve, with self diagnostic function to assures reliable operation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Litech","offers":[{"title":"Default Title","offer_id":51628960743740,"sku":null,"price":99999999.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0865\/5644\/2940\/files\/Room-Based_Air-Cooled_Plus_CRAC_Indoor_..jpg?v=1775198457"},{"product_id":"data-center-29","title":"Room-Based Inverter (Air-Cooled CRAC)","description":"\u003cp\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLMA Room-based Air-cooled Air conditioner provides precise temperature and humidity control for large and medium-size data rooms. It adopts high efficiency compressor and EC centrifugal fan to meet the requirements of 24 X 7 all-weather continuous operation. It is the ideal choice for green and energy-saving data centers and various electronic equipment rooms. It is manufactured with the world’s leading technologies and the most advanced components. Every product is fully tested before ex-factory to ensure performances and reliability.\u003c\/li\u003e\n\u003cli\u003eApplications: data center, communication equipment and computer room, MRI and CT room, other precision equipment environment, such as precision processing, electronic instrument workshop, museum, archives, high end wine cellar, medical\u003cbr\u003eequipment room, constant temperature and humidity laboratory, etc.\u003c\/li\u003e\n\u003cli\u003eAdopt hermetic inverter driven compressors and EC fans to minimize vibration and noise.\u003c\/li\u003e\n\u003cli\u003eHeat exchanger is using high-efficiency inner grooved copper tubes and Hydrophilic fins. Large heat exchanging area for better performances and efficiency.\u003c\/li\u003e\n\u003cli\u003eMultiple integrated protections, such as high\/low pressure and high discharge temperature protection, unit will shutdown automatically for protection, to avoid damages to the compressors.\u003c\/li\u003e\n\u003cli\u003eAdopt self-developed intelligent monitoring system, 7-inch LCD touch screen, friendly human-machine interface. It provides simple, convenient and real-time control and management of all the product functions, parameters query. Parameters display in graphic curve, with self diagnostic function to assures reliable and smooth operation.    \u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Litech","offers":[{"title":"Default Title","offer_id":51628961005884,"sku":null,"price":99999999.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0865\/5644\/2940\/files\/Room-Based_Inverter_Air-Cooled_CRAC_Indoor_1..jpg?v=1775188317"},{"product_id":"data-center-30","title":"Row-Based Inverter (Air-Cooled CRAC)","description":"\u003cp\u003eProduct Features:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLRA Row-based Air-cooled air conditioner adopts high efficiency DC inverter compressor and EC centrifugal fan to meet the requirements of 24 X 7 all-weather continuous operation. It is the ideal choice for green and energy-saving data centers and various electronic equipment rooms. It is manufactured with the world’s leading technologies and the most advanced components. Every product is fully tested before ex-factory to ensure performances and reliability.\u003c\/li\u003e\n\u003cli\u003eApplications: data center, communication equipment and computer room, MRI and CT room, other precision equipment environment, such as precision processing, electronic instrument workshop, museum, archives, high-end wine cellar, medical equipment room, constant temperature and humidity laboratory, etc.\u003c\/li\u003e\n\u003cli\u003eAdopt DC inverter compressors and EC fans to minimize vibration and noise.    \u003cbr\u003eHeat Heat exchanger is using high-efficiency inner grooved copper tubes and Hydrophilic fins. Large heat exchanging area for better performances and efficiency. is using high-efficiency inner grooved copper tubes and Hydrophilic fins. Large heat exchanging area for better performances and efficiency.\u003c\/li\u003e\n\u003cli\u003eMultiple integrated protections, such as high\/low pressure and high discharge temperature protection, unit will shutdown automatically for protection, to avoid damages to the compressors.\u003c\/li\u003e\n\u003cli\u003eAdopt self-developed intelligent monitoring system, 7-inch LCD touch screen, friendly human-machine interface. It provides simple, convenient and real-time control and management of all the product functions, parameters query. Parameters display in graphic curve, with self diagnostic function to assures reliable and smooth operation.\u003c\/li\u003e\n\u003cli\u003eAdopt electronic expansion valve, accurately controlling refrigerant flow to support the unit load.    \u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Litech","offers":[{"title":"Default Title","offer_id":51628961366332,"sku":null,"price":99999999.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0865\/5644\/2940\/files\/Row-Based_Inverter_Air-Cooled_CRAC_Indoor_..jpg?v=1775188317"},{"product_id":"data-center-31","title":"Structural Aluminium Ceiling","description":"\u003cp\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBuilt from strong, lightweight aluminum to reduce risks like zinc whiskers.\u003c\/li\u003e\n\u003cli\u003eSuspensions align precisely at 90° for stable installation.\u003c\/li\u003e\n\u003cli\u003eCan support loads up to 4.10kN\/418 kg per grid point.\u003c\/li\u003e\n\u003cli\u003eAvailable in grid sizes: 600×600mm, 600×1200mm, 1200×1200mm.\u003c\/li\u003e\n\u003cli\u003eCombines drop ceiling with overhead utility distribution.\u003c\/li\u003e\n\u003cli\u003eProvides mounting for containment barriers, partitions, and equipment.\u003c\/li\u003e\n\u003cli\u003eContinuous slot design allows easy installation of firefighting systems, trays, sensors, lights, and CCTV.\u003c\/li\u003e\n\u003cli\u003eOverhead plenum can be opened for access without affecting strength.\u003c\/li\u003e\n\u003cli\u003eFire-rated lightweight aluminum construction with bonded suspension for safe and stable installation.    \u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Litech","offers":[{"title":"Default Title","offer_id":51628962218300,"sku":null,"price":99999999.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0865\/5644\/2940\/files\/Structural_Aluminium_Ceiling.jpg?v=1775203317"},{"product_id":"data-center-32","title":"Raised Access Floor System","description":"\u003cp\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh strength to weight performance.\u003c\/li\u003e\n\u003cli\u003eUnique inbuilt stringer design.\u003c\/li\u003e\n\u003cli\u003eRecyclable \u0026amp; environment friendly system.\u003c\/li\u003e\n\u003cli\u003eGood acoustical properties.\u003c\/li\u003e\n\u003cli\u003eEnhanced lateral stability, flexural stiffness \u0026amp; mechanical resistance.\u003c\/li\u003e\n\u003cli\u003ePrecision in floor levels and positive alignment with the understructure system.\u003c\/li\u003e\n\u003cli\u003eEquipotential reinforcement for electrical continuity.\u003c\/li\u003e\n\u003cli\u003eFully grounded and fire-rated system, ensuring safety and compliance while supporting high load capacity and efficient airflow management    \u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Litech","offers":[{"title":"Default Title","offer_id":51628962251068,"sku":null,"price":99999999.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0865\/5644\/2940\/files\/Raised_Access_Floor_System.jpg?v=1775203228"},{"product_id":"data-center-33","title":"Cold Aisle Containment","description":"\u003cp\u003eLitech Cold Aisle Containment System is designed to optimize airflow management and reduce energy consumption In today's data centers. Litech's Aisle Containment System offers a cutting-edge solution for data centers seeking to enhance their operational efficiency and minimize their environmental footprint.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Highlights:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated PUE value within the module\u003c\/li\u003e\n\u003cli\u003eThe self-made row-based air conditioner provides near-end refrigeration, reducing air static pressure loss by 60%, and supports optional free cooling\u003c\/li\u003e\n\u003cli\u003eCustomizable design and configuration are available\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Litech","offers":[{"title":"Default Title","offer_id":51628962677052,"sku":null,"price":99999999.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0865\/5644\/2940\/files\/Cold_Aisle_Containment.jpg?v=1774950458"},{"product_id":"data-center-34","title":"Hot Aisle Containment","description":"\u003cp\u003eLitech Hot Aisle Containment System is designed to improved energy efficiency and enhanced cooling effectiveness by isolating the hot aisle - the space between the backs of the IT equipment racks where hot air is exhausted - with containment panels. This prevents hot air from mixing with the cooler supply air and circulating back to the equipment, which can increase the temperature of the air entering the servers and reduce their efficiency.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTelescopic chimney straight duct design\u003c\/li\u003e\n\u003cli\u003eHot Aisle Roof Enclosure\u003c\/li\u003e\n\u003cli\u003eVariety of door models\u003c\/li\u003e\n\u003cli\u003eWide range of customized chimney height options accommodate all data center ceiling heights\u003c\/li\u003e\n\u003cli\u003eEase of installation\u003c\/li\u003e\n\u003cli\u003eDoor Access control with optional mechanical or smart lock access control with ID card reader, Biometric Fingerprint Scanner, Digital keypad or Facial Recognition Access.\u003c\/li\u003e\n\u003cli\u003eAirflow Management Accessories\u003c\/li\u003e\n\u003cli\u003eMonitoring and Control Sensor\u003c\/li\u003e\n\u003cli\u003eCompatibility and Adaptability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Litech","offers":[{"title":"Default Title","offer_id":51628962808124,"sku":null,"price":99999999.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0865\/5644\/2940\/files\/Hot_Aisle_Containment.jpg?v=1774950370"},{"product_id":"data-center-36","title":"Modular Containerized Data Center (MCDC)","description":"\u003cp\u003eModular Containerized Data Center (MCDC) offers mixed IT (information technology) and CT (communication technology) power and energy infrastructure in a prefabricated ISO container allowing immediate installation of server and telecom equipment to shorten the deployment and commissioning time.\u003c\/p\u003e\n\u003cp\u003eMCDC is flexible to move and cost-saving. It is to be dustproof, waterproof and shock-resistant making it suitable to operate in various terrains as well as harshest environments. Designed for energy efficiency which enable power and cooling systems to match capacity and workload well, improving work efficiency and reducing over-configuration.\u003c\/p\u003e\n\u003cp\u003eMCDC is easy to install and scale up. With high scalability, containerized data centers can meet the changing demands of the organization rapidly and effortlessly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh energy efficiency\u003c\/li\u003e\n\u003cli\u003eReliability\u003c\/li\u003e\n\u003cli\u003eModularity\u003c\/li\u003e\n\u003cli\u003eICT cabinet flexibility\u003c\/li\u003e\n\u003cli\u003eICT load flexibility\u003c\/li\u003e\n\u003cli\u003eOptimized space use\u003c\/li\u003e\n\u003cli\u003eAlternative power supplies\u003c\/li\u003e\n\u003cli\u003eSecurity\u003c\/li\u003e\n\u003cli\u003eFire protection\u003c\/li\u003e\n\u003cli\u003eCentral management\u003c\/li\u003e\n\u003cli\u003eOptional features and customized layouts possible.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Litech","offers":[{"title":"Default Title","offer_id":51628963201340,"sku":null,"price":99999999.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0865\/5644\/2940\/files\/Modular_Containerized_Data_Center_MCDC_-02.jpg?v=1780624465"},{"product_id":"data-center-37","title":"Enterprise Micro Data Center (EMDC) V-Series","description":"\u003cp\u003eIntroducing Litech EMDC-V Series solution which offer a high performance data center solution in a compact form. ­ Comes in a self-contained data center architecture all-in-one design that fulfill enterprise needs rapidly at the edge and with the reliability your business need.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan lang=\"EN-ID\"\u003e\u003c\/span\u003eA high-performance data center solution in a compact form factor.\u003c\/li\u003e\n\u003cli\u003eIntegrated cabinet can simplify the installation process by eliminating the need for separate components.\u003c\/li\u003e\n\u003cli\u003eEquipped with intelligent large screen management system with real-time display of dynamic data application scenarios.­\u003c\/li\u003e\n\u003cli\u003eSpace and power optimization for cost-effective data management.\u003cstrong\u003e\u003cspan style=\"font-size: 11.0pt; line-height: 107%; font-family: 'Calibri',sans-serif; mso-ascii-theme-font: minor-latin; mso-fareast-font-family: Calibri; mso-fareast-theme-font: minor-latin; mso-hansi-theme-font: minor-latin; mso-bidi-font-family: 'Times New Roman'; mso-bidi-theme-font: minor-bidi; mso-ansi-language: EN-MY; mso-fareast-language: EN-US; mso-bidi-language: AR-SA;\"\u003e\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Litech","offers":[{"title":"Default Title","offer_id":51894667575612,"sku":null,"price":99999999.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0865\/5644\/2940\/files\/Smart_Rack_Enterprise_Micro_Data_Center_EMDC_V_Series..jpg?v=1775185258"},{"product_id":"data-center-38","title":"Enterprise Micro Data Center (EMDC) VR-Series","description":"\u003cp\u003eLitech EMDC-VR Series solution offers various customizable configuration of integration of cabinets, power supply and distribution systems, cooling systems, cabling systems, dynamic environment monitoring, management software, and much more. EMDC VR-Series innovate approach provides user the flexibility to data center design with fast deployment rate, best in class energy efficiency and low operating cost.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFully-enclosed design that comes with cold and hot aisle with contained airflow providing greater cooling efficiency.\u003c\/li\u003e\n\u003cli\u003eModular and scalable architectures that minimizes footprint\u003c\/li\u003e\n\u003cli\u003eCustomizable design and various predefined configuration\u003c\/li\u003e\n\u003cli\u003eSupport remote centralized management and constant\u003cbr\u003emonitoring to enhance operational efficiency\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Litech","offers":[{"title":"Default Title","offer_id":51628963496252,"sku":null,"price":99999999.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0865\/5644\/2940\/files\/Smart_Rack_Enterprise_Micro_Data_Center_EMDC_VR_Series..jpg?v=1775185257"},{"product_id":"data-center-39","title":"Enterprise Micro Data Center (EMDC) W-Series","description":"\u003cp\u003eLitech EMDC-W Series is specially designed for various enterprise to meet demand of edge computing providing extra U space for flexibility to your benefits. This is the versatile all-in-one, self-contained, prefabricated micro data centers solution for edge computing. With up to 5kW of integrated cooling, EMDC-W Series are ready to be deployed wherever you need them.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComes in 800mm wide cabinet structure that with side mounted air conditioning installation that gives users up to 40U of available space\u003c\/li\u003e\n\u003cli\u003eFull isolation of cold and hot aisles + CFD optimal air distribution with PUE as low as 1.2\u003c\/li\u003e\n\u003cli\u003eEquipped with intelligent large screen management system with real-time display of dynamic data application scenarios\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Litech","offers":[{"title":"Default Title","offer_id":51891632734524,"sku":null,"price":99999999.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0865\/5644\/2940\/files\/Smart_Rack_Enterprise_Micro_Data_Center_EMDC_W_Series..jpg?v=1775185257"},{"product_id":"data-center-40","title":"Enterprise Micro Data Center (EMDC) IR-Series","description":"\u003cp\u003eMeeting the demand of edge data center, Litech EMDC-IR Series offers a flexible module configuration of one + (1-8) single cabinet module.\u003c\/p\u003e\n\u003cp\u003eThe All-in-One solution that integrates cabinet, power supply and distribution, fire protection, cooling, monitoring and integrated cabling system that is modular thus providing a total data center solution. Standardized components, modular architecture, and quick on-demand construction to meet various customers demand with complete pre-installation and testing in factory to reduce construction time at site.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCabinets are directly coupled and assembled to form a double aisle closure on both hot and cold aisles.\u003c\/li\u003e\n\u003cli\u003eCabinets can be flexibly combined for future on-demand expansion.\u003c\/li\u003e\n\u003cli\u003eFlexible module configuration with reliable performance.\u003c\/li\u003e\n\u003cli\u003eEquipped with a monitoring system that can continuously monitor various functional modules.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Litech","offers":[{"title":"Default Title","offer_id":51628963922236,"sku":null,"price":99999999.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0865\/5644\/2940\/files\/Smart_Rack_Enterprise_Micro_Data_Center_EMDC_IR_Series..jpg?v=1775185258"},{"product_id":"data-center-62","title":"High-Resolution 17\" LCD KVM SWITCH 8 ports - RJ45","description":"","brand":"Litech","offers":[{"title":"Default Title","offer_id":51631616622908,"sku":"LTR-KVM-LCD-8P-RJ","price":4769.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0865\/5644\/2940\/files\/High-Resolution_17_LCD_KVM_SWITCH_4_Ports_ed39cca9-9b3b-4614-8be9-b905f311d5c4.jpg?v=1757560784"},{"product_id":"data-center-68","title":"Sliding Shelf - 400mm","description":"\u003cp\u003e\u003cstrong\u003eProduct Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVent design to improve air flow and effectively dissipate heats on equipments.\u003c\/li\u003e\n\u003cli\u003eSturdy front mounted cabinet shelf ensures long term durability and supports up to 20kg.\u003c\/li\u003e\n\u003cli\u003eDesigned to work with any 19\" rack providing additional storage space for mission critical equipment or for tools storing.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Specification\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable height=\"138\" style=\"border-collapse: collapse; width: 637px;\" width=\"398\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"width: 316.5px;\" width=\"197\"\u003e \u003ccol style=\"width: 320.5px;\" width=\"201\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 14.4pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.4pt; width: 148pt;\" width=\"197\" class=\"xl63\" height=\"19\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-left: none; width: 151pt;\" width=\"201\" class=\"xl63\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.4pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.4pt; border-top: none; width: 148pt;\" width=\"197\" class=\"xl64\" height=\"19\"\u003eNo of Rack Spaces\u003c\/td\u003e\n\u003ctd style=\"border-top: none; border-left: none; width: 151pt;\" width=\"201\" class=\"xl64\"\u003e1U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.4pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.4pt; border-top: none; width: 148pt;\" width=\"197\" class=\"xl64\" height=\"19\"\u003eRack Unit Width\u003c\/td\u003e\n\u003ctd style=\"border-top: none; border-left: none; width: 151pt;\" width=\"201\" class=\"xl64\"\u003e19\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.4pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.4pt; border-top: none; width: 148pt;\" width=\"197\" class=\"xl64\" height=\"19\"\u003eDimensions (W X D X H) (mm)\u003c\/td\u003e\n\u003ctd style=\"border-top: none; border-left: none; width: 151pt;\" width=\"201\" class=\"xl64\"\u003e483x350x44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28.8pt;\" height=\"38\"\u003e\n\u003ctd style=\"height: 28.8pt; border-top: none; width: 148pt;\" width=\"197\" class=\"xl64\" height=\"38\"\u003eColour\u003c\/td\u003e\n\u003ctd style=\"border-top: none; border-left: none; width: 151pt;\" width=\"201\" class=\"xl64\"\u003ePowder coated (RAL 9005) BLACK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.4pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.4pt; border-top: none; width: 148pt;\" width=\"197\" class=\"xl64\" height=\"19\"\u003eMaterial\u003c\/td\u003e\n\u003ctd style=\"border-top: none; border-left: none; width: 151pt;\" width=\"201\" class=\"xl64\"\u003eSteel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Litech","offers":[{"title":"Default Title","offer_id":51631617016124,"sku":"LTR-ACC-ESP-400","price":110.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0865\/5644\/2940\/files\/Sliding_Shelve_92b62a23-0b87-4afe-8fa0-5ea9b77c5b32.jpg?v=1757560795"},{"product_id":"data-center-71","title":"Litech UTP Cable Management Guide 1U Double Sided (Plastic)","description":"\u003cp\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDouble sided design with slotted ducts providing horizontal cable management on the rack’s front and back.\u003c\/li\u003e\n\u003cli\u003eSuitable for all standard 19 inch rack or cabinet for organizing trunk of cables.\u003c\/li\u003e\n\u003cli\u003eAvailable in 1U and 2U.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Specification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"814\" style=\"border-collapse: collapse; width: 963px;\" height=\"14\"\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"197\" style=\"width: 272px;\"\u003e \u003ccol width=\"617\" style=\"width: 690px;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl65\" width=\"197\" style=\"height: 14.4pt; width: 148pt;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"617\" style=\"border-left: none; width: 463pt;\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl66\" style=\"height: 14.4pt; border-top: none;\"\u003eMaterial\u003c\/td\u003e\n\u003ctd class=\"xl66\" style=\"border-top: none; border-left: none;\"\u003ePlastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl66\" style=\"height: 14.4pt; border-top: none;\"\u003eColour\u003c\/td\u003e\n\u003ctd class=\"xl66\" style=\"border-top: none; border-left: none;\"\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl66\" style=\"height: 14.4pt; border-top: none;\"\u003eType\u003c\/td\u003e\n\u003ctd class=\"xl66\" style=\"border-top: none; border-left: none;\"\u003e19” rack mountable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Litech","offers":[{"title":"1U","offer_id":52077877887292,"sku":"LTSS-CMG-DS01-P","price":55.0,"currency_code":"MYR","in_stock":true},{"title":"2U","offer_id":52077877920060,"sku":"LTSS-CMG-DS02-P","price":69.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0865\/5644\/2940\/files\/1U_Plastic_Double-Sided_Horizontal_Cable_Management_Panel_4519269a-84e8-4bd5-abff-7afa1b2785dc.jpg?v=1757560808"},{"product_id":"data-center-72","title":"Caged Nut ( 100 pcs )","description":"","brand":"Litech","offers":[{"title":"Default Title","offer_id":51894668165436,"sku":"LTR-CSM-CNUT-M6","price":40.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0865\/5644\/2940\/files\/Caged_Nut_ac697c4b-3b1c-4af8-8620-1de4b49e33b3.jpg?v=1757560810"},{"product_id":"data-center-73","title":"Pull Out Key Board Tray - 400mm","description":"","brand":"Litech","offers":[{"title":"Default Title","offer_id":51894668198204,"sku":"LTR-ACC-KBT-400","price":120.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0865\/5644\/2940\/files\/1U_Sliding_Keyboard_551a7a96-4945-4a6d-9601-ca330c8ea73a.jpg?v=1757560812"},{"product_id":"data-center-75","title":"High-Resolution 17\" LCD KVM SWITCH 4 ports VGA","description":"\u003cp\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e17.3” high-definition monitor design, supports resolution: 1600*900\u003c\/li\u003e\n\u003cli\u003eAll in one design(keyboard, mouse, monitor + kvm module); with 4 ports\u003c\/li\u003e\n\u003cli\u003eThe front USB design\u003c\/li\u003e\n\u003cli\u003eSupports installation depth: 360mm\u003c\/li\u003e\n\u003cli\u003eFolding handles \u0026amp; screw locking design\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Litech","offers":[{"title":"Default Title","offer_id":51891638731068,"sku":"LTR-KVM-LCD-4P-VGA","price":4069.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0865\/5644\/2940\/files\/High-Resolution_17_LCD_KVM_SWITCH_4_Ports_5f299d79-66e2-482d-93d9-04afa2ceaa17.jpg?v=1757560815"},{"product_id":"data-center-76","title":"High-Resolution 19” LCD KVM SWITCH 8 ports VGA","description":"\u003cp\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFront LCD Console (keyboard, mouse, monitor 19” ) + 8ports KVM Module design; It’s very flexible and convenient for combination\u003c\/li\u003e\n\u003cli\u003eKeyboard is with demountable design, with 9 different languages: American, English, German, French, Spanish, Swiss, Turkish, Russian, Italian\u003c\/li\u003e\n\u003cli\u003eIP optional ( IP card could be installed inside KVM module)\u003c\/li\u003e\n\u003cli\u003eThe front USB design\u003c\/li\u003e\n\u003cli\u003eCascade function support\u003c\/li\u003e\n\u003cli\u003eTotal length: 611mm, fit for 800-1200mm cabinet\u003c\/li\u003e\n\u003cli\u003eCable: 1.8\/3\/5m are available    \u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Litech","offers":[{"title":"Default Title","offer_id":51891639058748,"sku":"LTR-KVM-LCD-8P-VGA","price":4699.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0865\/5644\/2940\/files\/High-Resolution_19_LCD_KVM_SWITCH_8_Ports_8e546b71-9194-450f-8ac2-b2ac3e048f66.jpg?v=1757560816"},{"product_id":"data-center-51","title":"19\" 1U Micro Data Center Intelligent Controller (LMDCIC-01-S)","description":"\u003cp\u003eSet data acquisition, storage, linkage, local display in one, suitable for small and medium-sized computer room, cabinet, micro module dynamic and environmental monitoring, or industrial automation control.\u003c\/p\u003e\n\u003cp\u003eProduct Features:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePoint access capability\u003c\/li\u003e\n\u003cli\u003eStorage capacity\u003c\/li\u003e\n\u003cli\u003eAlarm management\u003c\/li\u003e\n\u003cli\u003eLinkage control\u003c\/li\u003e\n\u003cli\u003eStable and reliable performance\u003c\/li\u003e\n\u003cli\u003eSafety\u003c\/li\u003e\n\u003cli\u003eData upload and export\u003c\/li\u003e\n\u003cli\u003eFunction interface\u003c\/li\u003e\n\u003cli\u003eEasy installation    \u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Litech","offers":[{"title":"Default Title","offer_id":51632043884860,"sku":null,"price":99999999.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0865\/5644\/2940\/files\/19_1U_Micro_Data_Center_Intelligent_Controller_LMDCIC-01-S_5393704e-ab8a-4fec-b9d5-5ee966853899.jpg?v=1757560744"},{"product_id":"data-center-52","title":"Temperature \u0026 Humidity Sensor (LTH-02)","description":"\u003cp\u003eLTH-01-S temperature and humidity sensor measures and monitors both the temperature and humidity levels in the surrounding environment. Consist of a sensor element that detects changes in temperature and humidity and is suitable for data center computer room environment monitoring, computer room micro-modules, enterprise computer rooms, and places where environmental temperature and humidity need to be monitored.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh precision temperature and humidity sensor.\u003c\/li\u003e\n\u003cli\u003eDurable and compact ABS plastic chassis.\u003c\/li\u003e\n\u003cli\u003eComes with LCD screen for visual display and easy operation.\u003c\/li\u003e\n\u003cli\u003eAnti-electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eConnected to the intelligent data acquisition unit through RS485.\u003c\/li\u003e\n\u003cli\u003eSupports one channel of temperature collection and allows customization of the upper limit of temperature and humidity alarm.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Specification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"589\" style=\"border-collapse: collapse; width: 692px;\" height=\"126\"\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"197\" style=\"width: 249.5px;\"\u003e \u003ccol width=\"392\" style=\"width: 442.5px;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl64\" width=\"197\" style=\"height: 14.4pt; width: 148pt;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"xl64\" width=\"392\" style=\"border-left: none; width: 294pt;\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl63\" width=\"197\" style=\"height: 14.4pt; border-top: none; width: 148pt;\"\u003eInput voltage\u003c\/td\u003e\n\u003ctd class=\"xl63\" width=\"392\" style=\"border-top: none; border-left: none; width: 294pt;\"\u003e9V – 28V (\u0026lt; 0.5W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl63\" width=\"197\" style=\"height: 14.4pt; border-top: none; width: 148pt;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd class=\"xl63\" width=\"392\" style=\"border-top: none; border-left: none; width: 294pt;\"\u003e-20°C ~ +80°C [±0.5°C]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl63\" width=\"197\" style=\"height: 14.4pt; border-top: none; width: 148pt;\"\u003eRelative humidity\u003c\/td\u003e\n\u003ctd class=\"xl63\" width=\"392\" style=\"border-top: none; border-left: none; width: 294pt;\"\u003e0~100%RH [±4.5%RH]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl63\" width=\"197\" style=\"height: 14.4pt; border-top: none; width: 148pt;\"\u003eCommunication port\u003c\/td\u003e\n\u003ctd class=\"xl63\" width=\"392\" style=\"border-top: none; border-left: none; width: 294pt;\"\u003eRJ45, Modbus RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl63\" width=\"197\" style=\"height: 14.4pt; border-top: none; width: 148pt;\"\u003eBaud rate\u003c\/td\u003e\n\u003ctd class=\"xl63\" width=\"392\" style=\"border-top: none; border-left: none; width: 294pt;\"\u003e9600bps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl63\" width=\"197\" style=\"height: 14.4pt; border-top: none; width: 148pt;\"\u003eDimension\u003c\/td\u003e\n\u003ctd class=\"xl63\" width=\"392\" style=\"border-top: none; border-left: none; width: 294pt;\"\u003e71*60*30mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl63\" width=\"197\" style=\"height: 14.4pt; border-top: none; width: 148pt;\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"xl63\" width=\"392\" style=\"border-top: none; border-left: none; width: 294pt;\"\u003e0.040kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Litech","offers":[{"title":"Default Title","offer_id":51632043983164,"sku":null,"price":99999999.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0865\/5644\/2940\/files\/Temperature_Humidity_Sensor_LTH-02_61ed8e27-1929-4762-8961-d4546f1191f3.jpg?v=1757560746"},{"product_id":"data-center-53","title":"Smoke Alarm Detector (LSAD-01)","description":"\u003cp\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePhotoelectric detection method\u003c\/li\u003e\n\u003cli\u003eDigital Signal Processing analyses technique\u003c\/li\u003e\n\u003cli\u003eLow power consumption.\u003c\/li\u003e\n\u003cli\u003eHigh stability\u003c\/li\u003e\n\u003cli\u003eEasy installation\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Specification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"589\" style=\"border-collapse: collapse; width: 754px; height: 185px;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"197\" style=\"width: 279.5px;\"\u003e \u003ccol width=\"392\" style=\"width: 473.5px;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"19\" style=\"height: 11.6px;\"\u003e\n\u003ctd height=\"19\" class=\"xl64\" width=\"197\" style=\"height: 11.6px; width: 148pt;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"xl64\" width=\"392\" style=\"border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 294pt; height: 11.6px;\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.6px;\"\u003e\n\u003ctd height=\"19\" class=\"xl66\" width=\"197\" style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 148pt;\"\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd class=\"xl63\" width=\"392\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 294pt; height: 19.6px;\"\u003e9~14V( 220AC with adapter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.6px;\"\u003e\n\u003ctd height=\"19\" class=\"xl66\" width=\"197\" style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 148pt;\"\u003eOperating Current\u003c\/td\u003e\n\u003ctd class=\"xl63\" width=\"392\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 294pt; height: 19.6px;\"\u003e≤50mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.6px;\"\u003e\n\u003ctd height=\"19\" class=\"xl66\" width=\"197\" style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 148pt;\"\u003eDetecting Area\u003c\/td\u003e\n\u003ctd class=\"xl63\" width=\"392\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 294pt; height: 19.6px;\"\u003e20 Square Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.6px;\"\u003e\n\u003ctd height=\"19\" class=\"xl66\" width=\"197\" style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 148pt;\"\u003eWorking Temperature\u003c\/td\u003e\n\u003ctd class=\"xl63\" width=\"392\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 294pt; height: 19.6px;\"\u003e-10°C~60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.6px;\"\u003e\n\u003ctd height=\"19\" class=\"xl66\" width=\"197\" style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 148pt;\"\u003eWorking Humidity\u003c\/td\u003e\n\u003ctd class=\"xl63\" width=\"392\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 294pt; height: 19.6px;\"\u003e≤95% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.6px;\"\u003e\n\u003ctd height=\"19\" class=\"xl66\" width=\"197\" style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 148pt;\"\u003eSensitivity\u003c\/td\u003e\n\u003ctd class=\"xl63\" width=\"392\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 294pt; height: 19.6px;\"\u003eII Grade\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.6px;\"\u003e\n\u003ctd height=\"19\" class=\"xl66\" width=\"197\" style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 148pt;\"\u003eAlarm Type\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"392\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 294pt; height: 19.6px;\"\u003eNetwork Alarm Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.6px;\"\u003e\n\u003ctd height=\"19\" class=\"xl66\" width=\"197\" style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 148pt;\"\u003eAlarm Output\u003c\/td\u003e\n\u003ctd class=\"xl63\" width=\"392\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 294pt; height: 19.6px;\"\u003eNC\/NO(Contact DC28V 100mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.6px;\"\u003e\n\u003ctd height=\"19\" class=\"xl66\" width=\"197\" style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 148pt;\"\u003eInstallation Method\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"392\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 294pt; height: 19.6px;\"\u003eCeiling Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.6px;\"\u003e\n\u003ctd height=\"19\" class=\"xl66\" width=\"197\" style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 148pt;\"\u003eDimension\u003c\/td\u003e\n\u003ctd class=\"xl63\" width=\"392\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 294pt; height: 19.6px;\"\u003e104*51mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Litech","offers":[{"title":"Default Title","offer_id":51632044015932,"sku":null,"price":99999999.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0865\/5644\/2940\/files\/Smoke_Alarm_Detector_LSAD-01_d7ca3294-09b5-4ee0-bbe9-ab6328465b57.jpg?v=1757560748"},{"product_id":"data-center-54","title":"Water Leak Alarm Module With Water Sensor Cable (LLD-10)","description":"\u003cp\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePhotoelectric detection method\u003c\/li\u003e\n\u003cli\u003eDigital Signal Processing analyses technique\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003cli\u003eHigh stability\u003c\/li\u003e\n\u003cli\u003eEasy installation.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Specification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"589\" style=\"border-collapse: collapse; width: 842px;\" height=\"223\"\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"197\" style=\"width: 323.5px;\"\u003e \u003ccol width=\"392\" style=\"width: 517.5px;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl64\" width=\"197\" style=\"height: 14.4pt; width: 148pt;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"xl64\" width=\"392\" style=\"border-left: none; width: 294pt;\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl63\" width=\"197\" style=\"height: 14.4pt; border-top: none; width: 148pt;\"\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd class=\"xl63\" width=\"392\" style=\"border-top: none; border-left: none; width: 294pt;\"\u003e12V DC( 220AC with adapter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl63\" width=\"197\" style=\"height: 14.4pt; border-top: none; width: 148pt;\"\u003eOperating Current\u003c\/td\u003e\n\u003ctd class=\"xl63\" width=\"392\" style=\"border-top: none; border-left: none; width: 294pt;\"\u003e≤120mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl63\" width=\"197\" style=\"height: 14.4pt; border-top: none; width: 148pt;\"\u003eWorking Temperature\u003c\/td\u003e\n\u003ctd class=\"xl63\" width=\"392\" style=\"border-top: none; border-left: none; width: 294pt;\"\u003e-10°C~60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl63\" width=\"197\" style=\"height: 14.4pt; border-top: none; width: 148pt;\"\u003eWorking Humidity\u003c\/td\u003e\n\u003ctd class=\"xl63\" width=\"392\" style=\"border-top: none; border-left: none; width: 294pt;\"\u003e≤95% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl63\" width=\"197\" style=\"height: 14.4pt; border-top: none; width: 148pt;\"\u003eMounting Method\u003c\/td\u003e\n\u003ctd class=\"xl63\" width=\"392\" style=\"border-top: none; border-left: none; width: 294pt;\"\u003eDin Rail Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl63\" width=\"197\" style=\"height: 14.4pt; border-top: none; width: 148pt;\"\u003eSense Cable\u003c\/td\u003e\n\u003ctd class=\"xl63\" width=\"392\" style=\"border-top: none; border-left: none; width: 294pt;\"\u003e2 pins \/ 4 pins sensor cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl63\" width=\"197\" style=\"height: 14.4pt; border-top: none; width: 148pt;\"\u003eSensor Cable Length\u003c\/td\u003e\n\u003ctd class=\"xl63\" width=\"392\" style=\"border-top: none; border-left: none; width: 294pt;\"\u003eUp to 500m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl63\" width=\"197\" style=\"height: 14.4pt; border-top: none; width: 148pt;\"\u003eDetection Sensitive\u003c\/td\u003e\n\u003ctd class=\"xl63\" width=\"392\" style=\"border-top: none; border-left: none; width: 294pt;\"\u003e0-20k , response time less than 1 second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl63\" width=\"197\" style=\"height: 14.4pt; border-top: none; width: 148pt;\"\u003eRelay Output\u003c\/td\u003e\n\u003ctd class=\"xl63\" width=\"392\" style=\"border-top: none; border-left: none; width: 294pt;\"\u003e1SPDT usually open and close\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl63\" width=\"197\" style=\"height: 14.4pt; border-top: none; width: 148pt;\"\u003eOutput Rated Power\u003c\/td\u003e\n\u003ctd class=\"xl63\" width=\"392\" style=\"border-top: none; border-left: none; width: 294pt;\"\u003e60VDC\/1A or \/220VAC\/1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl63\" width=\"197\" style=\"height: 14.4pt; border-top: none; width: 148pt;\"\u003eSignal Output\u003c\/td\u003e\n\u003ctd class=\"xl63\" width=\"392\" style=\"border-top: none; border-left: none; width: 294pt;\"\u003eRS485 MODBUS-RTU protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Litech","offers":[{"title":"Default Title","offer_id":51632044048700,"sku":null,"price":99999999.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0865\/5644\/2940\/files\/Water_Leak_Alarm_Module_With_Water_Sensor_Cable_LLD-10_ce9966de-6ae2-48f3-aa37-a15349112a2c.jpg?v=1757560751"},{"product_id":"data-center-55","title":"Water Leak Sensor (LWS-01)","description":"\u003cp\u003eRoof panels to enclose the top of the cold aisle and create a sealed environment for efficient airflow management. These panels help prevent hot air recirculation by containing the cold air within the aisle, ensuring that it is directed towards the IT equipment for optimal cooling. ¬Cold aisle containment roof panels are typically made of lightweight and durable materials and they are designed to fit securely on top of the cold aisle structure.\u003c\/p\u003e\n\u003cp\u003eBy installing roof panels in the cold aisle containment system, data center operators can improve cooling efficiency, reduce energy consumption, and maintain a consistent temperature throughout the data center. By installing roof panels in the cold aisle containment system, data center operators can improve cooling efficiency, reduce energy consumption, and maintain a consistent temperature throughout the data center.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eClear lightweight panels allow for light pass through.\u003c\/li\u003e\n\u003cli\u003eFramed panels can be lifted off to access above contained area for maintenance.\u003c\/li\u003e\n\u003cli\u003eFramed panels can be pre-installed for fast installation\u003c\/li\u003e\n\u003cli\u003eFlexible, modular design and customizable to different aisle lengths and widths.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Specification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"814\" style=\"border-collapse: collapse; width: 948px;\" height=\"149\"\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"197\" style=\"width: 264.5px;\"\u003e \u003ccol width=\"617\" style=\"width: 682.5px;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl64\" width=\"197\" style=\"height: 14.4pt; width: 148pt;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"xl64\" width=\"617\" style=\"border-left: none; width: 463pt;\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl63\" width=\"197\" style=\"height: 14.4pt; width: 148pt;\"\u003eOperating Power\u003c\/td\u003e\n\u003ctd class=\"xl63\" width=\"617\" style=\"border-left: none; width: 463pt;\"\u003e12V DC, customizable to DC24V.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl63\" width=\"197\" style=\"height: 14.4pt; border-top: none; width: 148pt;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd class=\"xl63\" width=\"617\" style=\"border-top: none; border-left: none; width: 463pt;\"\u003e-10°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl63\" width=\"197\" style=\"height: 14.4pt; border-top: none; width: 148pt;\"\u003eOutput Form\u003c\/td\u003e\n\u003ctd class=\"xl63\" width=\"617\" style=\"border-top: none; border-left: none; width: 463pt;\"\u003eRelay (Load Current 30mA), Relay Output NC\/NO selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl63\" width=\"197\" style=\"height: 14.4pt; border-top: none; width: 148pt;\"\u003eStatic Power Consumption\u003c\/td\u003e\n\u003ctd class=\"xl63\" width=\"617\" style=\"border-top: none; border-left: none; width: 463pt;\"\u003e≤0.3W, Alarm Power Consumption: ≤0.5W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl63\" width=\"197\" style=\"height: 14.4pt; border-top: none; width: 148pt;\"\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd class=\"xl63\" width=\"617\" style=\"border-top: none; border-left: none; width: 463pt;\"\u003e20% RH to 100% RH, False Alarm Rate \u0026lt; 100ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl63\" width=\"197\" style=\"height: 14.4pt; border-top: none; width: 148pt;\"\u003eHigh\/Low-Level Output\u003c\/td\u003e\n\u003ctd class=\"xl63\" width=\"617\" style=\"border-top: none; border-left: none; width: 463pt;\"\u003eVL is 0V (+0.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl63\" width=\"197\" style=\"height: 14.4pt; border-top: none; width: 148pt;\"\u003eLoad Capacity\u003c\/td\u003e\n\u003ctd class=\"xl63\" width=\"617\" style=\"border-top: none; border-left: none; width: 463pt;\"\u003eVH is 5V or 12V (±0.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl63\" width=\"197\" style=\"height: 14.4pt; border-top: none; width: 148pt;\"\u003eSolid State Relay\u003c\/td\u003e\n\u003ctd class=\"xl63\" width=\"617\" style=\"border-top: none; border-left: none; width: 463pt;\"\u003e500mA (can be customized for higher current, up to 1A).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl63\" width=\"197\" style=\"height: 14.4pt; border-top: none; width: 148pt;\"\u003eHigh-Level M is 3k. Note\u003c\/td\u003e\n\u003ctd class=\"xl63\" width=\"617\" style=\"border-top: none; border-left: none; width: 463pt;\"\u003eWhen the high-level output is 12V, the supply voltage should be higher than 16V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl63\" width=\"197\" style=\"height: 14.4pt; border-top: none; width: 148pt;\"\u003eDetection Cable\u003c\/td\u003e\n\u003ctd class=\"xl63\" width=\"617\" style=\"border-top: none; border-left: none; width: 463pt;\"\u003ePoint-type detection points on the sensing cable, spaced around 10cm apart\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl63\" width=\"197\" style=\"height: 14.4pt; border-top: none; width: 148pt;\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd class=\"xl63\" width=\"617\" style=\"border-top: none; border-left: none; width: 463pt;\"\u003eComes with a standard 1.5-meter detection cable, customizable for different cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Litech","offers":[{"title":"Default Title","offer_id":51632044212540,"sku":null,"price":99999999.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0865\/5644\/2940\/files\/Water_Leak_Sensor_LWS-01_12927421-2d74-4e8d-9def-0c38df2d5b73.jpg?v=1757560753"},{"product_id":"data-center-56","title":"Rack Mounted Automatic Fire Suppression Unit (LFSU)","description":"\u003cp\u003eThe rack mounted automatic fire suppression unit provides protection for equipment stored in rack enclosures and cabinet.\u003c\/p\u003e\n\u003cp\u003eThe fire suppression unit is self-contained and comes with built-in fire detection sensors.\u003cbr\u003eDetectors are activated and suppression unit is automatically triggered to release FM200 extinguishing gas which is proven to be safe and reliable without causing damage to the equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFully self-contained fire detection \u0026amp; suppression system\u003c\/li\u003e\n\u003cli\u003eCompact 1U,2U or 4U chassis mounting\u003c\/li\u003e\n\u003cli\u003eFaster response to in-cabinet fire incidents\u003c\/li\u003e\n\u003cli\u003eUse FM-200 systems which reach extinguishing levels in 10 seconds or less\u003c\/li\u003e\n\u003cli\u003eComes in various activation mode depending on user's requirement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Specification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable height=\"192\" style=\"border-collapse: collapse; width: 874px; height: 246.712px;\" width=\"766\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width: 222px;\" width=\"237\"\u003e \u003ccol style=\"width: 188px;\" width=\"201\"\u003e \u003ccol style=\"width: 316px;\" width=\"172\"\u003e \u003ccol style=\"width: 147px;\" width=\"156\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; width: 178pt;\" width=\"237\" class=\"xl64\" height=\"19\"\u003eParameter\u003c\/td\u003e\n\u003ctd style=\"border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 151pt; text-align: center; height: 19.6px;\" width=\"201\" class=\"xl65\"\u003eLFSU-01\u003c\/td\u003e\n\u003ctd style=\"border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 129pt; height: 19.6px; text-align: center;\" width=\"172\" class=\"xl65\"\u003eLFSU-02\u003c\/td\u003e\n\u003ctd style=\"border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 117pt; height: 19.6px; text-align: center;\" width=\"156\" class=\"xl65\"\u003eLFSU-04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 178pt; text-align: left;\" width=\"237\" class=\"xl63\" height=\"19\"\u003eStorage capacity (kg)\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 151pt; text-align: center; height: 19.6px;\" width=\"201\" class=\"xl66\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 129pt; height: 19.6px; text-align: center;\" width=\"172\" class=\"xl66\"\u003e3\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 117pt; height: 19.6px; text-align: center;\" width=\"156\" class=\"xl66\"\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 41px;\" height=\"41\"\u003e\n\u003ctd style=\"height: 41px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 178pt;\" width=\"237\" class=\"xl63\" height=\"41\"\u003eStorage pressure (20°C, MPa)\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 151pt; text-align: center; height: 41px;\" width=\"201\" class=\"xl66\"\u003e1.6 ± 0.2\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 129pt; height: 41px; text-align: center;\" width=\"172\" class=\"xl66\"\u003e1.2\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 117pt; height: 41px; text-align: center;\" width=\"156\" class=\"xl66\"\u003e1.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 41px;\" height=\"41\"\u003e\n\u003ctd style=\"height: 41px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 178pt;\" width=\"237\" class=\"xl63\" height=\"41\"\u003eEffective Protection Range (m³)\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 151pt; text-align: center; height: 41px;\" width=\"201\" class=\"xl66\"\u003e≤3\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 129pt; height: 41px; text-align: center;\" width=\"172\" class=\"xl66\"\u003e4\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 117pt; height: 41px; text-align: center;\" width=\"156\" class=\"xl66\"\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 178pt;\" width=\"237\" class=\"xl63\" height=\"19\"\u003eExtinguishing time (s)\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 151pt; text-align: center; height: 19.6px;\" width=\"201\" class=\"xl66\"\u003e≤30\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 129pt; height: 19.6px; text-align: center;\" width=\"172\" class=\"xl66\"\u003e≤10\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 117pt; height: 19.6px; text-align: center;\" width=\"156\" class=\"xl66\"\u003e≤10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 178pt;\" width=\"237\" class=\"xl63\" height=\"19\"\u003eChassis Height\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 151pt; height: 19.6px; text-align: center;\" width=\"201\" class=\"xl66\"\u003e1U\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 129pt; height: 19.6px; text-align: center;\" width=\"172\" class=\"xl66\"\u003e2U\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 117pt; height: 19.6px; text-align: center;\" width=\"156\" class=\"xl66\"\u003e4U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 0px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 66.7125px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 178pt;\" width=\"237\" class=\"xl63\" height=\"57\" rowspan=\"3\"\u003eDimension (L*W*H)(mm)\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 151pt; height: 66.7125px; text-align: center;\" width=\"201\" class=\"xl67\" rowspan=\"3\"\u003e442*482*43.6\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 129pt; height: 66.7125px; text-align: center;\" width=\"172\" class=\"xl67\" rowspan=\"3\"\u003e530*480*88\u003cbr\u003eIntelligent type:\u003cbr\u003e570*480*88\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 117pt; height: 66.7125px; text-align: center;\" width=\"156\" class=\"xl67\" rowspan=\"3\"\u003e530*480*176\u003cbr\u003eIntelligent type:\u003cbr\u003e570*480*176\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 0px;\" height=\"19\"\u003e\u003c\/tr\u003e\n\u003ctr style=\"height: 66.7125px;\" height=\"19\"\u003e\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 178pt;\" width=\"237\" class=\"xl63\" height=\"19\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 151pt; height: 19.6px; text-align: center;\" width=\"201\" class=\"xl66\"\u003e0~50°C\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 129pt; height: 19.6px; text-align: center;\" width=\"172\" class=\"xl66\"\u003e0~50°C\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 117pt; height: 19.6px; text-align: center;\" width=\"156\" class=\"xl66\"\u003e0~50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Litech","offers":[{"title":"Default Title","offer_id":51632044278076,"sku":null,"price":99999999.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0865\/5644\/2940\/files\/Rack_Mounted_Automatic_Fire_Suppression_Unit_LFSU_6b6ef424-fe0b-4022-bcb7-44cf1066a3a7.jpg?v=1757560756"},{"product_id":"data-center-57","title":"Audible and Visual Alarm (LAA-01)","description":"\u003cp\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFeaturing a high-quality shell made from ABS material built to withstand impacts, guaranteeing long-lasting reliability.\u003c\/li\u003e\n\u003cli\u003eEasy installation that comes with loud 110dB and RED strobe when alarm system is triggered boasting exceptional light transmission ensuring effective visibility.\u003c\/li\u003e\n\u003cli\u003eWith exceptional low-temperature and heat resistance, it can maintain optimal functionality regardless of environmental conditions.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Specification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable height=\"79\" style=\"border-collapse: collapse; width: 610px;\" width=\"268\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width: 127px;\" width=\"138\"\u003e \u003ccol style=\"width: 482px;\" width=\"130\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd style=\"height: 15.0pt; width: 103pt;\" width=\"138\" class=\"xl64\" height=\"20\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 97pt;\" width=\"130\" class=\"xl65\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd style=\"height: 15.0pt; width: 103pt;\" width=\"138\" class=\"xl66\" height=\"20\"\u003eWorking Voltage\u003c\/td\u003e\n\u003ctd style=\"width: 97pt;\" width=\"130\" class=\"xl63\"\u003eDC9V-12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd style=\"height: 15.0pt; width: 103pt;\" width=\"138\" class=\"xl66\" height=\"20\"\u003eRated Current\u003c\/td\u003e\n\u003ctd style=\"width: 97pt;\" width=\"130\" class=\"xl63\"\u003e300mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd style=\"height: 15.0pt; width: 103pt;\" width=\"138\" class=\"xl66\" height=\"20\"\u003eSiren sound\u003c\/td\u003e\n\u003ctd style=\"width: 97pt;\" width=\"130\" class=\"xl63\"\u003e115dB ± 3dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd style=\"height: 15.0pt; width: 103pt;\" width=\"138\" class=\"xl66\" height=\"20\"\u003eSize\u003c\/td\u003e\n\u003ctd style=\"width: 97pt;\" width=\"130\" class=\"xl63\"\u003e122 x 72 x 43mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd style=\"height: 15.0pt; width: 103pt;\" width=\"138\" class=\"xl66\" height=\"20\"\u003eMaterial\u003c\/td\u003e\n\u003ctd style=\"width: 97pt;\" width=\"130\" class=\"xl63\"\u003eABS housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Litech","offers":[{"title":"Default Title","offer_id":51632044376380,"sku":null,"price":99999999.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0865\/5644\/2940\/files\/Audible_and_Visual_Alarm_LAA-01_71cb7ba3-a0ee-42a2-b0c9-54fb580b21fc.jpg?v=1757560758"},{"product_id":"data-center-77","title":"Smoke Alarm Detector (LSAD-02)","description":"\u003cp\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eState of the art detector for highest safety\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003cli\u003eSends alarm information to intelligent integrated management platform\u003c\/li\u003e\n\u003cli\u003eHigh stability\u003c\/li\u003e\n\u003cli\u003eEasy installation\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Specification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable height=\"112\" style=\"border-collapse: collapse; width: 705px;\" width=\"589\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width: 255px;\" width=\"197\"\u003e \u003ccol style=\"width: 449px;\" width=\"392\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 14.4pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.4pt; width: 148pt;\" width=\"197\" class=\"xl66\" height=\"19\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-left: none; width: 294pt;\" width=\"392\" class=\"xl66\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.4pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.4pt; border-top: none; width: 148pt;\" width=\"197\" class=\"xl65\" height=\"19\"\u003eAmbient Humidity\u003c\/td\u003e\n\u003ctd style=\"border-top: none; border-left: none; width: 294pt;\" width=\"392\" class=\"xl65\"\u003e12V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.4pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.4pt; border-top: none; width: 148pt;\" width=\"197\" class=\"xl65\" height=\"19\"\u003eOperation Current\u003c\/td\u003e\n\u003ctd style=\"border-top: none; border-left: none; width: 294pt;\" width=\"392\" class=\"xl65\"\u003eMonitor \u0026lt;10μA ; Alarm Status: \u0026lt;30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.4pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.4pt; border-top: none; width: 148pt;\" width=\"197\" class=\"xl65\" height=\"19\"\u003eOperation Temperature\u003c\/td\u003e\n\u003ctd style=\"border-top: none; border-left: none; width: 294pt;\" width=\"392\" class=\"xl65\"\u003e-10°C~+65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.4pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.4pt; border-top: none; width: 148pt;\" width=\"197\" class=\"xl65\" height=\"19\"\u003eAmbient Humidity\u003c\/td\u003e\n\u003ctd style=\"border-top: none; border-left: none; width: 294pt;\" width=\"392\" class=\"xl65\"\u003e≤95%\u003cspan class=\"font5\"\u003e）\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.4pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.4pt; border-top: none; width: 148pt;\" width=\"197\" class=\"xl65\" height=\"19\"\u003eExternal Dimension\u003c\/td\u003e\n\u003ctd style=\"border-top: none; border-left: none; width: 294pt;\" width=\"392\" class=\"xl65\"\u003e75mm×51.8mm×38.5mm (with base)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.4pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.4pt; border-top: none; width: 148pt;\" width=\"197\" class=\"xl65\" height=\"19\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"border-top: none; border-left: none; width: 294pt;\" width=\"392\" class=\"xl65\"\u003e75g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Litech","offers":[{"title":"Default Title","offer_id":51891640959292,"sku":null,"price":99999999.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0865\/5644\/2940\/files\/Smoke_Alarm_Detector_LSAD-02_61b4f541-8fdb-4ed8-aac8-f38b115081e0.jpg?v=1757560819"},{"product_id":"data-center-46","title":"Precision Power Distribution Cabinet","description":"\u003cp\u003eLitech design and fabricate full range of power distribution products for requirements of medium to large data centers, Litech Precison Power Distribution Cabinet provides an optimal, flexible and easy to integrate power distribution solution. This space-saving solution is easy to move and adapt to future reconfigurations of the data center, it offers superior power protection and monitoring, and the flexibility \u0026amp; scalability to match your actual power distribution requirements. Not only does it improve availability, it reduces the cost of initial investment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLCD display and keypad for monitoring, setting parameters.\u003c\/li\u003e\n\u003cli\u003eMonitoring the current of each branch circuit breaker.\u003c\/li\u003e\n\u003cli\u003eBuilt-in RS232 interface for remote monitoring.\u003c\/li\u003e\n\u003cli\u003eSNMP interfaces increasing availability.\u003c\/li\u003e\n\u003cli\u003eICT load flexibility.\u003c\/li\u003e\n\u003cli\u003eCabling from top or bottom.\u003c\/li\u003e\n\u003cli\u003eBreaker trip alarms.\u003c\/li\u003e\n\u003cli\u003eBreaker over current alarm with alarm threshold configurable.\u003c\/li\u003e\n\u003cli\u003eOptional Current unbalance and phase sequence error alarm.\u003c\/li\u003e\n\u003cli\u003eCan customized to any requirements.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Litech","offers":[{"title":"Default Title","offer_id":51632355148092,"sku":null,"price":99999999.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0865\/5644\/2940\/files\/Precision_Power_Distribution_Cabinet.jpg?v=1775204618"},{"product_id":"data-center-47","title":"Power Distribution Panels","description":"\u003cp data-start=\"62\" data-end=\"247\"\u003eLitech is a licensed switchboard manufacturer providing reliable power distribution panels for data centers, designed and delivered in compliance with international and local standards.\u003c\/p\u003e\n\u003cp data-start=\"249\" data-end=\"499\"\u003eThe rack-mount power distribution panel is built to efficiently distribute power to multiple devices within a standard rack. Ideal for data centers and server rooms, it offers a space-saving design, easy installation, and simplified power management.\u003c\/p\u003e\n\u003cp data-start=\"501\" data-end=\"617\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eAvailable in various configurations, it provides a flexible and efficient solution for different power requirements.\u003c\/p\u003e\n\u003cp data-start=\"501\" data-end=\"617\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong\u003eProduct Specification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"2219\" style=\"border-collapse: collapse; width: 1664pt; height: 218px;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"336\" style=\"width: 336px;\"\u003e \u003ccol width=\"271\" style=\"width: 351px;\"\u003e \u003ccol width=\"541\" style=\"width: 384px;\"\u003e \u003ccol width=\"367\" style=\"width: 394px;\"\u003e \u003ccol width=\"352\" span=\"2\" style=\"width: 382px;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"19\" style=\"height: 19.6px;\"\u003e\n\u003ctd height=\"19\" class=\"xl63\" width=\"336\" style=\"height: 19.6px; width: 252pt;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"5\" class=\"xl69\" width=\"1883\" style=\"border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 1412pt; text-align: center; height: 19.6px;\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.6px;\"\u003e\n\u003ctd height=\"19\" class=\"xl63\" width=\"336\" style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 252pt;\"\u003e \u003c\/td\u003e\n\u003ctd class=\"xl63\" width=\"271\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 203pt; text-align: center; height: 19.6px;\"\u003e\u003cstrong\u003eModule 1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"xl66\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; text-align: center; height: 19.6px;\"\u003e\u003cstrong\u003eModule 2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"xl66\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; text-align: center; height: 19.6px;\"\u003e\u003cstrong\u003eModule 3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"xl66\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; text-align: center; height: 19.6px;\"\u003e\u003cstrong\u003eModule 4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"xl66\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; text-align: center; height: 19.6px;\"\u003e\u003cstrong\u003eModule 5\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 0px;\"\u003e\n\u003ctd rowspan=\"2\" height=\"38\" class=\"xl72\" width=\"336\" style=\"height: 41.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 252pt;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd rowspan=\"2\" class=\"xl67\" width=\"271\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 203pt; text-align: center; height: 41.6px;\"\u003e130 mm x 442 mm x 450 mm\u003c\/td\u003e\n\u003ctd rowspan=\"2\" class=\"xl75\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; text-align: center; height: 41.6px;\"\u003e263 mm x 442 mm x 450 mm\u003c\/td\u003e\n\u003ctd rowspan=\"2\" class=\"xl67\" width=\"367\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 275pt; text-align: center; height: 41.6px;\"\u003e263 mm x 442 mm x 450 mm \/\u003cbr\u003e130 mm x 442 mm x 450 mm (additional component)\u003c\/td\u003e\n\u003ctd rowspan=\"2\" class=\"xl67\" width=\"352\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 264pt; text-align: center; height: 41.6px;\"\u003e263 mm x 442 mm x 450 mm \/\u003cbr\u003e130 mm x 442 mm x 450 mm (additional component)\u003c\/td\u003e\n\u003ctd rowspan=\"2\" class=\"xl67\" width=\"352\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 264pt; text-align: center; height: 41.6px;\"\u003e263 mm x 442 mm x 450 mm \/\u003cbr\u003e130 mm x 442 mm x 450 mm (additional component)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 41.6px;\"\u003e\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.6px;\"\u003e\n\u003ctd height=\"19\" class=\"xl65\" width=\"336\" style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 252pt;\"\u003eGeneral Input\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"271\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 203pt; text-align: center; height: 19.6px;\"\u003e63A MCB\u003c\/td\u003e\n\u003ctd class=\"xl64\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; text-align: center; height: 19.6px;\"\u003e100 A disconnector switch\u003c\/td\u003e\n\u003ctd class=\"xl64\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; text-align: center; height: 19.6px;\"\u003e100 A disconnector switch\u003c\/td\u003e\n\u003ctd class=\"xl64\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; text-align: center; height: 19.6px;\"\u003e125 A MCB\u003c\/td\u003e\n\u003ctd class=\"xl64\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; text-align: center; height: 19.6px;\"\u003e100 A disconnector switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.6px;\"\u003e\n\u003ctd height=\"19\" class=\"xl64\" style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor;\"\u003eUPS Input\u003c\/td\u003e\n\u003ctd class=\"xl64\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; text-align: center; height: 19.6px;\"\u003e1 x D63A\/1P MCB\u003c\/td\u003e\n\u003ctd class=\"xl64\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; text-align: center; height: 19.6px;\"\u003e1 x D63A\/3P MCB\u003c\/td\u003e\n\u003ctd class=\"xl64\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; text-align: center; height: 19.6px;\"\u003e2 X D63A \/3P MCB\u003c\/td\u003e\n\u003ctd class=\"xl64\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; text-align: center; height: 19.6px;\"\u003e3 x D63A\/3P MCB\u003c\/td\u003e\n\u003ctd class=\"xl64\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; text-align: center; height: 19.6px;\"\u003e2 X D63A\/3P MCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.6px;\"\u003e\n\u003ctd height=\"19\" class=\"xl64\" style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor;\"\u003eUPS Output\u003c\/td\u003e\n\u003ctd class=\"xl64\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; text-align: center; height: 19.6px;\"\u003e1 x C63A\/1P MCB\u003c\/td\u003e\n\u003ctd class=\"xl64\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; text-align: center; height: 19.6px;\"\u003e1 x C63A\/1P MCB\u003c\/td\u003e\n\u003ctd class=\"xl64\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; text-align: center; height: 19.6px;\"\u003e2 x C63A \/3P MCB\u003c\/td\u003e\n\u003ctd class=\"xl64\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; text-align: center; height: 19.6px;\"\u003e3 x C63A\/3P MCB\u003c\/td\u003e\n\u003ctd class=\"xl64\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; text-align: center; height: 19.6px;\"\u003e2 X C63A\/3P MCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.6px;\"\u003e\n\u003ctd height=\"19\" class=\"xl64\" style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor;\"\u003eUPS Bypass\u003c\/td\u003e\n\u003ctd class=\"xl64\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; text-align: center; height: 19.6px;\"\u003e1 X C63A\/1P MCB\u003c\/td\u003e\n\u003ctd class=\"xl64\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; text-align: center; height: 19.6px;\"\u003e1 X C63A\/1P MCB\u003c\/td\u003e\n\u003ctd class=\"xl64\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; text-align: center; height: 19.6px;\"\u003e1 X C63A\/1P MCB\u003c\/td\u003e\n\u003ctd class=\"xl64\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; text-align: center; height: 19.6px;\"\u003e1 x C63A\/3p MCB\u003c\/td\u003e\n\u003ctd class=\"xl64\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; text-align: center; height: 19.6px;\"\u003e1 X C63A\/3P MCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.6px;\"\u003e\n\u003ctd height=\"19\" class=\"xl64\" style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor;\"\u003ePower Distribution for Smart Cooling Product\u003c\/td\u003e\n\u003ctd class=\"xl64\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; text-align: center; height: 19.6px;\"\u003e1 x C40A\/1P MCB + 1 x C25A\/1P MCB\u003c\/td\u003e\n\u003ctd class=\"xl64\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; text-align: center; height: 19.6px;\"\u003e3 x C40A\/1P MCB + 3 x C25A\/1P MCB\u003c\/td\u003e\n\u003ctd class=\"xl64\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; text-align: center; height: 19.6px;\"\u003e3 x C40A\/1P MCB + 3 x C25A\/1P MCB\u003c\/td\u003e\n\u003ctd class=\"xl64\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; text-align: center; height: 19.6px;\"\u003e4 x C40A\/1P MCB + 4 X C25A\/1P MCB\u003c\/td\u003e\n\u003ctd class=\"xl64\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; text-align: center; height: 19.6px;\"\u003e6 X C40A\/1P MCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.6px;\"\u003e\n\u003ctd height=\"19\" class=\"xl64\" style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor;\"\u003ePower Distribution for IT Equipment\u003c\/td\u003e\n\u003ctd class=\"xl64\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; text-align: center; height: 19.6px;\"\u003e4 x C40A\/1P MCB\u003c\/td\u003e\n\u003ctd class=\"xl64\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; text-align: center; height: 19.6px;\"\u003e12 x C40A\/1P MCB\u003c\/td\u003e\n\u003ctd class=\"xl64\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; text-align: center; height: 19.6px;\"\u003e12 x C40A\/1P MCB\u003c\/td\u003e\n\u003ctd class=\"xl64\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; text-align: center; height: 19.6px;\"\u003e20 x C40A\/1P MCB\u003c\/td\u003e\n\u003ctd class=\"xl64\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; text-align: center; height: 19.6px;\"\u003e12 X C40A\/1P MCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.6px;\"\u003e\n\u003ctd height=\"19\" class=\"xl64\" style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor;\"\u003eSPD Switch\u003c\/td\u003e\n\u003ctd class=\"xl64\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; text-align: center; height: 19.6px;\"\u003e1 x C32A\/4P MCB\u003c\/td\u003e\n\u003ctd class=\"xl64\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; text-align: center; height: 19.6px;\"\u003e1 x C32A\/4P MCB\u003c\/td\u003e\n\u003ctd class=\"xl64\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; text-align: center; height: 19.6px;\"\u003e1 x C32A\/4P MCB\u003c\/td\u003e\n\u003ctd class=\"xl64\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; text-align: center; height: 19.6px;\"\u003e1 x C32A\/4P MCB\u003c\/td\u003e\n\u003ctd class=\"xl64\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; text-align: center; height: 19.6px;\"\u003e1 x C32A\/4P MCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Litech","offers":[{"title":"Default Title","offer_id":51632355213628,"sku":null,"price":99999999.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0865\/5644\/2940\/files\/Power_Distribution_Panel_2.jpg?v=1775204619"},{"product_id":"data-center-58","title":"Smart Rack Management Solution - Smart Rack Lock ( LDS-67)","description":"\u003cp\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupports RS485, remote,fingerprint, password, IC card, bluetooth, mechanical and electronic key unlocking\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Specification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable height=\"273\" style=\"border-collapse: collapse; width: 828px; height: 373.2px;\" width=\"589\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width: 257px;\" width=\"197\"\u003e \u003ccol style=\"width: 570px;\" width=\"392\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; width: 148pt;\" width=\"197\" class=\"xl64\" height=\"19\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 294pt; height: 19.6px;\" width=\"392\" class=\"xl64\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 148pt;\" width=\"197\" class=\"xl63\" height=\"19\"\u003eOverall dimension\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 294pt; height: 19.6px;\" width=\"392\" class=\"xl63\"\u003e240mm x 38mm x 45mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 148pt;\" width=\"197\" class=\"xl63\" height=\"19\"\u003eRated Voltage\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 294pt; height: 19.6px;\" width=\"392\" class=\"xl63\"\u003eDC 12V ± 10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 148pt;\" width=\"197\" class=\"xl63\" height=\"19\"\u003eOperating system\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 294pt; height: 19.6px;\" width=\"392\" class=\"xl63\"\u003eRTOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 148pt;\" width=\"197\" class=\"xl63\" height=\"19\"\u003ePower consumption\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 294pt; height: 19.6px;\" width=\"392\" class=\"xl63\"\u003e≤2W (25°C, 65%RH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 148pt;\" width=\"197\" class=\"xl63\" height=\"19\"\u003eRated Current\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 294pt; height: 19.6px;\" width=\"392\" class=\"xl63\"\u003e≤50mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 148pt;\" width=\"197\" class=\"xl63\" height=\"19\"\u003ePeak Current\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 294pt; height: 19.6px;\" width=\"392\" class=\"xl63\"\u003e≤100mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 148pt;\" width=\"197\" class=\"xl63\" height=\"19\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 294pt; height: 19.6px;\" width=\"392\" class=\"xl63\"\u003e-10~-65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 148pt;\" width=\"197\" class=\"xl63\" height=\"19\"\u003eOperating humidity\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 294pt; height: 19.6px;\" width=\"392\" class=\"xl63\"\u003e5 - 90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 148pt;\" width=\"197\" class=\"xl63\" height=\"19\"\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 294pt; height: 19.6px;\" width=\"392\" class=\"xl63\"\u003eRS485, BLE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.4px;\" height=\"38\"\u003e\n\u003ctd style=\"height: 20.4px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 148pt;\" width=\"197\" class=\"xl63\" height=\"38\"\u003eNumber of users\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 294pt; height: 20.4px;\" width=\"392\" class=\"xl63\"\u003e100 groups (100 fingerprints + 100 group of passwords + 100 cards)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 148pt;\" width=\"197\" class=\"xl63\" height=\"19\"\u003eIC Card parameters\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 294pt; height: 19.6px;\" width=\"392\" class=\"xl63\"\u003e13.56MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 148pt;\" width=\"197\" class=\"xl63\" height=\"19\"\u003eCard type\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 294pt; height: 19.6px;\" width=\"392\" class=\"xl63\"\u003eIC, NFC, CPU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 148pt;\" width=\"197\" class=\"xl63\" height=\"19\"\u003eFingerprint\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 294pt; height: 19.6px;\" width=\"392\" class=\"xl63\"\u003eSearching time ≤1s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 148pt;\" width=\"197\" class=\"xl63\" height=\"19\"\u003ePassword\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 294pt; height: 19.6px;\" width=\"392\" class=\"xl63\"\u003e6 digits (support virtual password function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 148pt;\" width=\"197\" class=\"xl63\" height=\"19\"\u003eLock cyclinder\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 294pt; height: 19.6px;\" width=\"392\" class=\"xl63\"\u003eOptional (mechanical\/electronic lock cyclinder)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 148pt;\" width=\"197\" class=\"xl63\" height=\"19\"\u003eControl wire\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 294pt; height: 19.6px;\" width=\"392\" class=\"xl63\"\u003eStandard length; 400mm, customized\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 148pt;\" width=\"197\" class=\"xl63\" height=\"19\"\u003eStandard accessories\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 294pt; height: 19.6px;\" width=\"392\" class=\"xl63\"\u003eF2016; F3003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 148pt;\" width=\"197\" class=\"xl63\" height=\"19\"\u003eOptional accessories\u003c\/td\u003e\n\u003ctd style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 294pt; height: 19.6px;\" width=\"392\" class=\"xl63\"\u003eF2017; F2018; A2209; F4 door sensor series; F1 lock cam series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Litech","offers":[{"title":"Default Title","offer_id":51632356458812,"sku":null,"price":99999999.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0865\/5644\/2940\/files\/Smart_Rack_Management_Solution_-_Smart_Rack_Lock_LDS-67_2ad1cbb9-4535-46c4-9e9f-22fd7e2ee62d.jpg?v=1757560760"},{"product_id":"data-center-59","title":"Smart Rack Management Solution - Smart Rack Lock (LDS-68-S)","description":"\u003cp\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial grade hardware design\u003c\/li\u003e\n\u003cli\u003eSupport IC card, remote door opening, key door opening\u003c\/li\u003e\n\u003cli\u003eSupports standard interface: RS485 communication, standard Modbus RTU protocol\u003c\/li\u003e\n\u003cli\u003eWide operating temperature range\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Specification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable height=\"136\" style=\"border-collapse: collapse; width: 724px;\" width=\"589\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width: 237px;\" width=\"197\"\u003e \u003ccol style=\"width: 486px;\" width=\"392\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 14.4pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.4pt; width: 148pt;\" width=\"197\" class=\"xl66\" height=\"19\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-left: none; width: 294pt;\" width=\"392\" class=\"xl66\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.4pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.4pt; border-top: none; width: 148pt;\" width=\"197\" class=\"xl65\" height=\"19\"\u003eDimension\u003c\/td\u003e\n\u003ctd style=\"border-top: none; border-left: none; width: 294pt;\" width=\"392\" class=\"xl65\"\u003e196mm x 41mm x 52mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.4pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.4pt; border-top: none; width: 148pt;\" width=\"197\" class=\"xl65\" height=\"19\"\u003eProcessor\u003c\/td\u003e\n\u003ctd style=\"border-top: none; border-left: none; width: 294pt;\" width=\"392\" class=\"xl65\"\u003e32-bit ARM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.4pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.4pt; border-top: none; width: 148pt;\" width=\"197\" class=\"xl65\" height=\"19\"\u003eOperating System\u003c\/td\u003e\n\u003ctd style=\"border-top: none; border-left: none; width: 294pt;\" width=\"392\" class=\"xl65\"\u003eRTOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.4pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.4pt; border-top: none; width: 148pt;\" width=\"197\" class=\"xl65\" height=\"19\"\u003eProtocol\u003c\/td\u003e\n\u003ctd style=\"border-top: none; border-left: none; width: 294pt;\" width=\"392\" class=\"xl65\"\u003eModbus RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.4pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.4pt; border-top: none; width: 148pt;\" width=\"197\" class=\"xl65\" height=\"19\"\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd style=\"border-top: none; border-left: none; width: 294pt;\" width=\"392\" class=\"xl65\"\u003eRS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.4pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.4pt; border-top: none; width: 148pt;\" width=\"197\" class=\"xl65\" height=\"19\"\u003eBaud Rate\u003c\/td\u003e\n\u003ctd style=\"border-top: none; border-left: none; width: 294pt;\" width=\"392\" class=\"xl65\"\u003e19200bps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.4pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.4pt; border-top: none; width: 148pt;\" width=\"197\" class=\"xl65\" height=\"19\"\u003eNumber Of Offline Cards\u003c\/td\u003e\n\u003ctd style=\"border-top: none; border-left: none; width: 294pt;\" width=\"392\" class=\"xl67\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.4pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.4pt; border-top: none; width: 148pt;\" width=\"197\" class=\"xl65\" height=\"19\"\u003eCard Detection Range\u003c\/td\u003e\n\u003ctd style=\"border-top: none; border-left: none; width: 294pt;\" width=\"392\" class=\"xl65\"\u003e1~2cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.4pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.4pt; border-top: none; width: 148pt;\" width=\"197\" class=\"xl65\" height=\"19\"\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd style=\"border-top: none; border-left: none; width: 294pt;\" width=\"392\" class=\"xl65\"\u003e9-16VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.4pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.4pt; border-top: none; width: 148pt;\" width=\"197\" class=\"xl65\" height=\"19\"\u003eRated Current\u003c\/td\u003e\n\u003ctd style=\"border-top: none; border-left: none; width: 294pt;\" width=\"392\" class=\"xl65\"\u003e≤50mA\/12VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.4pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.4pt; border-top: none; width: 148pt;\" width=\"197\" class=\"xl65\" height=\"19\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"border-top: none; border-left: none; width: 294pt;\" width=\"392\" class=\"xl65\"\u003e-40°C~85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Litech","offers":[{"title":"Default Title","offer_id":51632356524348,"sku":null,"price":99999999.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0865\/5644\/2940\/files\/Smart_Rack_Management_Solution_-_Smart_Rack_Lock_LDS-68-S_b105415c-98d8-42c3-9101-69305e7110ff.jpg?v=1757560763"},{"product_id":"data-center-60","title":"Smart Rack Management Solution - Smart Rack Lock (LDS-69-S)","description":"\u003cp\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFast Fingerprint Identification - Fingerprints can be identified in a few seconds, sensitive and fast response, easy to use.\u003c\/li\u003e\n\u003cli\u003eMulti-factor Authentication - Supports card swiping, fingerprint and password modes to be used alone or in combination using the RS485 standard interface.\u003c\/li\u003e\n\u003cli\u003eEasy to Use - Comes with OLED Display that give a seamless, fast and efficient experience.\u003c\/li\u003e\n\u003cli\u003eMultiple Usage Environment - Can be apply to various types of usage environment eg: computer rooms, cabinet equipment and etc.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Specification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"589\" style=\"border-collapse: collapse; width: 731px; height: 373.4px;\" height=\"297\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"197\" style=\"width: 255px;\"\u003e \u003ccol width=\"392\" style=\"width: 475px;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"19\" style=\"height: 19.6px;\"\u003e\n\u003ctd height=\"19\" class=\"xl64\" width=\"197\" style=\"height: 19.6px; width: 148pt;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"xl64\" width=\"392\" style=\"border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 294pt; height: 19.6px;\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.6px;\"\u003e\n\u003ctd height=\"19\" class=\"xl63\" width=\"197\" style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 148pt;\"\u003eOperating voltage\u003c\/td\u003e\n\u003ctd class=\"xl63\" width=\"392\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 294pt; height: 19.6px;\"\u003eVoltage range 9~16VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.6px;\"\u003e\n\u003ctd height=\"19\" class=\"xl63\" width=\"197\" style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 148pt;\"\u003eRated current\u003c\/td\u003e\n\u003ctd class=\"xl63\" width=\"392\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 294pt; height: 19.6px;\"\u003e100mA @ 12V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.6px;\"\u003e\n\u003ctd height=\"19\" class=\"xl63\" width=\"197\" style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 148pt;\"\u003eCard detection range\u003c\/td\u003e\n\u003ctd class=\"xl63\" width=\"392\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 294pt; height: 19.6px;\"\u003e3~5cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.6px;\"\u003e\n\u003ctd height=\"19\" class=\"xl63\" width=\"197\" style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 148pt;\"\u003eCard identification time\u003c\/td\u003e\n\u003ctd class=\"xl63\" width=\"392\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 294pt; height: 19.6px;\"\u003e\u0026lt; 0.2s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.6px;\"\u003e\n\u003ctd height=\"19\" class=\"xl63\" width=\"197\" style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 148pt;\"\u003eCard reading alert\u003c\/td\u003e\n\u003ctd class=\"xl63\" width=\"392\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 294pt; height: 19.6px;\"\u003eSound and light prompts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 20.6px;\"\u003e\n\u003ctd height=\"19\" class=\"xl63\" width=\"197\" style=\"height: 20.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 148pt;\"\u003eCard reading type\u003c\/td\u003e\n\u003ctd class=\"xl63\" width=\"392\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 294pt; height: 20.6px;\"\u003eIC card, fingerprint, password\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.6px;\"\u003e\n\u003ctd height=\"19\" class=\"xl63\" width=\"197\" style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 148pt;\"\u003eInterface mode\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"392\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 294pt; height: 19.6px;\"\u003eRS485, Wiegand34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.6px;\"\u003e\n\u003ctd height=\"19\" class=\"xl63\" width=\"197\" style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 148pt;\"\u003eCommunication distance\u003c\/td\u003e\n\u003ctd class=\"xl63\" width=\"392\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 294pt; height: 19.6px;\"\u003eWiegand: ≤100M; RS485: ≤1200M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.6px;\"\u003e\n\u003ctd height=\"19\" class=\"xl63\" width=\"197\" style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 148pt;\"\u003eFingerprint capacity\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"392\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 294pt; height: 19.6px;\"\u003e120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"38\" style=\"height: 19.6px;\"\u003e\n\u003ctd height=\"38\" class=\"xl63\" width=\"197\" style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 148pt;\"\u003eFingerprint search time \u0026lt;1 second\u003c\/td\u003e\n\u003ctd class=\"xl63\" width=\"392\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 294pt; height: 19.6px;\"\u003e\u0026lt; 1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.6px;\"\u003e\n\u003ctd height=\"19\" class=\"xl63\" width=\"197\" style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 148pt;\"\u003eRejection rate\u003c\/td\u003e\n\u003ctd class=\"xl63\" width=\"392\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 294pt; height: 19.6px;\"\u003e\u0026lt; 1 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.6px;\"\u003e\n\u003ctd height=\"19\" class=\"xl63\" width=\"197\" style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 148pt;\"\u003eFalse recognition rate\u003c\/td\u003e\n\u003ctd class=\"xl66\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; height: 19.6px;\"\u003e\u0026lt;0.001%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.6px;\"\u003e\n\u003ctd height=\"19\" class=\"xl63\" width=\"197\" style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 148pt;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd class=\"xl66\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; height: 19.6px;\"\u003e1.3\" (128*64 dot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.6px;\"\u003e\n\u003ctd height=\"19\" class=\"xl63\" width=\"197\" style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 148pt;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd class=\"xl66\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; height: 19.6px;\"\u003e-20°C~60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.6px;\"\u003e\n\u003ctd height=\"19\" class=\"xl63\" width=\"197\" style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 148pt;\"\u003eOperating humidity\u003c\/td\u003e\n\u003ctd class=\"xl66\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; height: 19.6px;\"\u003e5%~95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.6px;\"\u003e\n\u003ctd height=\"19\" class=\"xl63\" width=\"197\" style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 148pt;\"\u003eMaterial\u003c\/td\u003e\n\u003ctd class=\"xl66\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; height: 19.6px;\"\u003ePlastic frosted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.6px;\"\u003e\n\u003ctd height=\"19\" class=\"xl63\" width=\"197\" style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 148pt;\"\u003eDimension\u003c\/td\u003e\n\u003ctd class=\"xl66\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; height: 19.6px;\"\u003e88mm(L) x 88mm(W) x 16mm(H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.6px;\"\u003e\n\u003ctd height=\"19\" class=\"xl63\" width=\"197\" style=\"height: 19.6px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 148pt;\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"xl66\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; height: 19.6px;\"\u003e150g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Litech","offers":[{"title":"Default Title","offer_id":51632356819260,"sku":null,"price":99999999.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0865\/5644\/2940\/files\/Smart_Rack_Management_Solution_-_Smart_Rack_Lock_LDS-69-S_0b6f8e3b-c369-4fa7-b881-3e0f3febdb91.jpg?v=1757560765"},{"product_id":"data-center-70","title":"HDMI KVM Switch","description":"","brand":"Litech","offers":[{"title":"8 Port","offer_id":52077877428540,"sku":"LTR-KVM-9108HA","price":1583.0,"currency_code":"MYR","in_stock":true},{"title":"16 Port","offer_id":52077877461308,"sku":"LTR-KVM-9116HA","price":2293.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0865\/5644\/2940\/files\/HDMI_KVM_Switch-01_aa92f63b-cd98-4985-83fc-dd455a2c8f8c.jpg?v=1757560806"},{"product_id":"data-center-06","title":"Fan AC 120mmx 120mm x 38mm ( standalone sales - without wiring)","description":"","brand":"Litech","offers":[{"title":"Default Title","offer_id":51726132150588,"sku":"LTR-CSM-FAN-AC","price":45.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0865\/5644\/2940\/files\/AC_Fan_e350d2b5-0e93-4a14-8aab-dccd110e357f.jpg?v=1757560594"},{"product_id":"data-center-07","title":"Fan DC 120mmx 120mm x 38mm ( standalone sales - without wiring)","description":"","brand":"Litech","offers":[{"title":"Default Title","offer_id":51726132445500,"sku":"LTR-CSM-FAN-DC","price":50.0,"currency_code":"MYR","in_stock":true}]},{"product_id":"data-center-08","title":"Adjustable Feet ( 4 pcs)","description":"","brand":"Litech","offers":[{"title":"Default Title","offer_id":51726132478268,"sku":"LTR-CSM-ADJ","price":30.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0865\/5644\/2940\/files\/Adjustable_Feet_744f1197-39d6-41f8-83b5-10a0f3045b14.jpg?v=1757560597"},{"product_id":"data-center-09","title":"Castor Wheel ( 4 pcs)","description":"","brand":"Litech","offers":[{"title":"Default Title","offer_id":51726132511036,"sku":"LTR-CSM-CAST","price":34.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0865\/5644\/2940\/files\/Castor_Wheel_e8ca5154-9c9d-4354-a62d-afccfbaa2b4f.jpg?v=1757560600"},{"product_id":"data-center-13","title":"Vented Cantilever Shelf - 400mm Depth","description":"\u003cp\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVent design to improve air flow and effectively dissipate heats on equipments.\u003c\/li\u003e\n\u003cli\u003eSturdy front mounted cabinet shelf ensures long term durability and supports up to 20kg.\u003c\/li\u003e\n\u003cli\u003eDesigned to work with any 19\" rack providing additional storage space for mission critical equipment or for tools storing.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Specification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"373\" style=\"border-collapse: collapse; width: 689px;\" height=\"86\"\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"138\" style=\"width: 295.5px;\"\u003e \u003ccol width=\"235\" style=\"width: 392.5px;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl63\" width=\"138\" style=\"height: 14.4pt; width: 103pt;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"xl63\" width=\"235\" style=\"border-left: none; width: 176pt;\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl64\" width=\"138\" style=\"height: 14.4pt; border-top: none; width: 103pt;\"\u003eNo of Rack Spaces\u003c\/td\u003e\n\u003ctd class=\"xl64\" width=\"235\" style=\"border-top: none; border-left: none; width: 176pt;\"\u003e1U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl64\" width=\"138\" style=\"height: 14.4pt; border-top: none; width: 103pt;\"\u003eRack Unit Width\u003c\/td\u003e\n\u003ctd class=\"xl64\" width=\"235\" style=\"border-top: none; border-left: none; width: 176pt;\"\u003e19\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl64\" width=\"138\" style=\"height: 14.4pt; border-top: none; width: 103pt;\"\u003eMaximum static load\u003c\/td\u003e\n\u003ctd class=\"xl64\" width=\"235\" style=\"border-top: none; border-left: none; width: 176pt;\"\u003eUp to 20kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl64\" width=\"138\" style=\"height: 14.4pt; border-top: none; width: 103pt;\"\u003eColour\u003c\/td\u003e\n\u003ctd class=\"xl64\" width=\"235\" style=\"border-top: none; border-left: none; width: 176pt;\"\u003ePowder coated (RAL 9005) BLACK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.4pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl64\" width=\"138\" style=\"height: 14.4pt; border-top: none; width: 103pt;\"\u003eMaterial\u003c\/td\u003e\n\u003ctd class=\"xl64\" width=\"235\" style=\"border-top: none; border-left: none; width: 176pt;\"\u003eSteel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Litech","offers":[{"title":"1U","offer_id":52077856325948,"sku":"LTR-ACC-VCS1-400","price":90.0,"currency_code":"MYR","in_stock":true},{"title":"2U","offer_id":52077856358716,"sku":"LTR-ACC-VCS2-400","price":95.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0865\/5644\/2940\/files\/19_Vented_Cantilever_Shelve.jpg?v=1745287995"}],"url":"https:\/\/litech.com.my\/collections\/data-center-1.oembed","provider":"Litech","version":"1.0","type":"link"}